Trigger types

Edge

Window

Hysteresis

Sources

CH 0 (front panel BNC connector)

CH 1 (front panel BNC connector)

TRIG (front panel BNC connector)

Trigger level range

CH 0, CH 1

100% of FS

TRIG (external trigger)

±5 V

Trigger level resolution

10 bits (1 in 1,024)

Edge trigger sensitivity

CH 0, CH 1

2.5% FS up to 50 MHz, increasing to 5% FS at 100 MHz, Warranted

TRIG (external trigger, Vpk-pk)

0.25 V up to 100 MHz, increasing to 1 V at 200 MHz, Warranted

Level accuracy

CH 0, CH 1

±3.5% FS up to 10 MHz

TRIG (external trigger)

±0.35 V (±3.5% of FS) up to 10 MHz

Trigger jitter

≤80 psrms [1]1 Within ±5 °C of self-calibration temperature.

Trigger filters

Low-frequency (LF) reject

50 kHz

High-frequency (HF) reject

50 kHz

1 Within ±5 °C of self-calibration temperature.