Making a Connection
- Updated2024-06-13
- 1 minute(s) read
Making a Connection
Both the scanning command, dut1->busA;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters dut1 and busA, result in the following connection:
signal connected to DUT1 is routed to busA
Special attention needs to be given to the behavior of the relays associated with the pass-through channels (k0...k67). These relays (k0...k67) are in their open state when the pass-through channels (chN to dutN) are connected and vice versa. If you intend to use the niSwitch Relay Control VI or niSwitch_RelayControl function to operate these relays, please note that closing relays (k0...k67) will disconnect the pass through channels (chN to dutN).
Because the pass-through channels (chN to dutN) are connected in its power-on or reset state, these channels may need to be disconnected during a scanning operation. In order to disconnect the channels during a scan, set the Scan Mode property to None, or the NISWITCH_ATTR_SCAN_MODE attribute to NISWITCH_VAL_NONE.