Learns perspective calibration information to correct perspective distortion introduced by a camera that is not perpendicular to the plane of the object under inspection.

Examples

Supported Image Types

8-bit unsigned grayscale 16-bit unsigned grayscale 32-bit RGB 16-bit signed grayscale floating point grayscale 32-bit HSL

IMAQ Learn Perspective Calibration

cgenclasstagrefflat.gif

Calibration Template Image is a reference to the image containing calibration information.

cgenclasstagrefflat.gif

Image is a reference to the source image.

ccclst.gif

Reference Points is the set of reference points to use in learning a calibration. Create the reference points manually or use the IMAQ Calibration Target to Points - Circular Dots 2 VI.

c1dnclst.gif

Pixel Coordinates are the coordinates of 3 reference points in the image, in pixels.

cdbl.gif

X is the x-coordinate of the point.

cdbl.gif

Y is the y-coordinate of the point.

c1dnclst.gif

Real World Coordinates are the relative locations of the dots in the real world.

cu32.gif

X is the x-coordinate of the point.

cu32.gif

Y is the y-coordinate of the point.

cenum.gif

Unit is the unit of the Real World Coordinates.

cnclst.gif

Image Size specifies the size of the calibration template image.

cu32.gif

X is the horizontal size of the image.

cu32.gif

Y is the vertical size of the image.

cerrcodeclst.gif

error in (no error) describes the error status before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.

cbool.gif

status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.

ci32.gif

code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.

cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.

igenclasstagrefflat.gif

Calibration Template Image Out is the reference to the output image.

ierrcodeclst.gif

error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.

ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

ii32.gif

code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.

istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.