NI-Sync C API Reference

NISYNC_ATTR_8021AS_PRIORITY1

  • Updated2023-02-21
  • 1 minute(s) read
Data
Type
Access Applies to Coercion High-Level Functions
ViInt32 R/W N/A None None

Description

Specifies or returns the 1st order priority assigned to the 802.1AS clock used by the time reference specified by activeItem. This attribute is used in the execution of the Best Master Clock algorithm (BMCA). This attribute can range from 0 to 255. A lower value increases the priority. The default value is 246.

Note Note  
  • This attribute is supported only on certain targets. Refer to Target Support for Timing Attributes and Functions to determine whether or not this attribute is supported on your target.
  • You must specify the time reference using the activeItem parameter when querying this attribute.