ScopeReferenceTrigger Properties
- Updated2023-09-06
- 2 minute(s) read
ScopeReferenceTrigger Properties
The ScopeReferenceTrigger type exposes the following members.
Properties
Name | Description | |
---|---|---|
![]() | Delay |
Gets or sets the trigger delay time, in seconds. The trigger delay time is the length of time the digitizer waits after receiving the trigger. The event that occurs when the trigger delay elapses is the Reference Event.
|
![]() | DetectorLocation |
Gets or sets which reference trigger detection circuitry to use on the instrument.
|
![]() | Hysteresis |
Specifies the size of the hysteresis window on either side of the trigger level.
|
![]() | QuietTimeMin |
Gets or sets the amount of time the trigger circuit must not detect a signal above the trigger level, or below the trigger level if the trigger slope is negative, before the trigger is armed.
|
![]() | ReferencePosition |
Gets or sets the position of the Reference Event in the waveform record.
When the digitizer detects a trigger, it waits the length of time specified by Delay.
The event that occurs when the delay time elapses is the Reference Event. The Reference Event is relative to the start of the record and is a percentage of the record length.
For example, the value 50.0 corresponds to the center of the waveform record and 0.0 corresponds to the first element in the waveform record.
|
![]() | Window |
Gets the ScopeWindowReferenceTrigger sub-object.
|