Device Specific:Vector Signal Transceiver:Triggers:Sync Script Trigger Dist Line Property
- Updated2024-05-08
- 1 minute(s) read
Device Specific:Vector Signal Transceiver:Triggers:Sync Script Trigger Dist Line Property
Short Name: Sync Script Trigger Dist Line
Property of niRFSG
Specifies which external trigger line distributes the synchronized Script Trigger signal. Use the Active Channel property to specify the name of the Script Trigger you are configuring. When synchronizing the Script Trigger, configure all devices to use the same Script Trigger distribution line.
To set this property, the NI-RFSG device must be in the Configuration state.
Supported Devices: PXIe-5644/5645/5646
Default Value: "" (empty string)
Valid Values: PXI_Trig0, PXI_Trig1, PXI_Trig2, PXI_Trig3, PXI_Trig4, PXI_Trig5, PXI_Trig6, PXI_Trig7, PFI0
Related Topics
Synchronizing Sample Clock and Sampled Reference Clock Signals
Refer to the Synchronization Using NI-RFSA and NI-RFSG topic appropriate to your device for more information about device synchronization for vector signal transceivers.
Remarks
The following table lists the characteristics of this property.
| Datatype | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Channel-based | Yes |
| Resettable | Yes |