NI 5652 Calibration
- Updated2024-05-08
- 2 minute(s) read
NI 5652 Calibration
Owning Palette: External CalibrationUse the NI 5652 Calibration VIs to calibrate your PXI/PXIe-5650/5651/5652 device. Refer to the calibration procedure for your device for more information about device calibration.
Palette Object | Description |
---|---|
niRFSG 5652 Initialize ALC Calibration |
Generates external calibration constants for calibrating the automatic leveling control (ALC). Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Configure ALC Calibration |
Configures the PXI/PXIe-5650/5651/5652 for the next automatic leveling control (ALC) calibration point and waits for the output signal to settle. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Adjust ALC Calibration |
Calculates calibration information pertaining to the ALC of the PXI/PXIe-5650/5651/5652. This calculation is based on user-supplied measurements. The calibration information is stored in the driver session, and you can later write this information to the device. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Initialize Attenuator Calibration |
Generates external calibration constants for calibrating the attenuator. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Configure Attenuator Calibration |
Configures the PXI/PXIe-5650/5651/5652 for the next attenuator calibration point and waits for the output signal to settle. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Adjust Attenuator Calibration |
Calculates calibration information pertaining to the selected attenuator on the PXI/PXIe-5650/5651/5652. This calculation is based on user-supplied measurements. The calibration information is stored in the driver session, and you can later write this information to the device. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Update ALC Limits Table |
Updates the PXI/PXIe-5650/5651/5652 ALC limits table, which determines the attenuator and path NI-RFSG uses for each frequency and power combination. This VI computes the ALC limits table based on calibration data saved during the ALC and attenuator adjustment procedures as well as temperature correction data saved when the device was manufactured. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Validate ALC Limits Table |
Validates the PXI/PXIe-5650/5651/5652 ALC limits table, which determines the attenuator and path NI-RFSG uses for each frequency and power combination. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Initialize Reference Clock Calibration |
Generates external calibration constants for calibrating the 10 MHz reference. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Configure Reference Clock Calibration |
Configures the PXI/PXIe-5650/5651/5652 with specific settings for calibrating the 10 MHz OCXO reference. Supported Devices: PXI/PXIe-5650/5651/5652 |
niRFSG 5652 Adjust Reference Clock Calibration |
Calculates calibration information pertaining to the 10 MHz OCXO reference of the PXI/PXIe-5650/5651/5652. This calculation is based on user-supplied measurements. The calibration information is stored in the driver session, and you can later write this information to the device. Supported Devices: PXI/PXIe-5650/5651/5652 |