niRFSG_ConfigureDeembeddingTableInterpolationLinear
- Updated2024-05-08
- 1 minute(s) read
niRFSG_ConfigureDeembeddingTableInterpolationLinear
ViStatus niRFSG_ConfigureDeembeddingTableInterpolationLinear (ViSession vi, ViConstString port, ViConstString tableName, ViInt32 format);
Purpose
Selects the linear interpolation method. If the carrier frequency does not match a row in the de-embedding table, NI-RFSG performs a linear interpolation based on the entries in the de-embedding table to determine the parameters to use for de-embedding.
Supported Devices: PXIe-5830/5831/5832/5840/5841/5842
Parameters
Input | ||||||||
Name | Type | Description | ||||||
vi | ViSession | Identifies your instrument session. The ViSession handle is obtained from the niRFSG_init function or the niRFSG_InitWithOptions function and identifies a particular instrument session. | ||||||
port | ViConstString | Specifies the name of the port. The only valid value for the PXIe-5840/5841/5842 is "" (empty string). | ||||||
tableName | ViConstString | Specifies the name of the table. | ||||||
format | ViInt32 | Specifies the format of parameters to interpolate.
|
Return Value
Name | Type | Description | ||||||||
status | ViStatus | Returns the status code of this operation. The status code either indicates success or describes an error or warning condition. Examine the status code from each call to an instrument driver function to determine if an error occurred.
To obtain a text description of the error code, call the niRFSG_GetError function. The general meaning of the status code is as follows:
|
||||||||