rfsa c api reference

NIRFSA_ATTR_DOWNCONVERTER_GAIN

  • Updated2024-05-08
  • 1 minute(s) read

NIRFSA_ATTR_DOWNCONVERTER_GAIN

Specific Attribute

Data
type
Access High Level Functions
ViReal64 RO None

Description

Returns the net signal gain for the NI-RFSA device at the current NI-RFSA settings and temperature. NI-RFSA scales the acquired I/Q and spectrum data from the digitizer using the value of this attribute.

For a vector signal analyzer (VSA), the system is defined as the RF downconverter and all interfaces between the RF IN connector on the RF downconverter front panel and the IF IN connector on the digitizer front panel. For a spectrum monitoring receiver, the system is defined as the RF preselector, RF downconverter, and IF conditioning modules including all interfaces between the RF IN connector on the RF preselector module front panel and the IF IN connector on the digitizer front panel.

Default Value: N/A

Supported Devices: PXI-5600, PXIe-5601/5603/5605/5606 (external digitizer mode), PXIe-5644/5645/5646, PXI-5661, PXIe-5663/5663E/5665/5667/5668, PXIe-5693/5694/5698, PXIe-5830/5831/5832/5840/5841