Calibration
- Updated2023-12-28
- 2 minute(s) read
Calibration
Owning Palette: NI-RFPM VIsInstalled With: NI-RFPM
Use the NI-RFPM Calibration VIs to control calibration operations for the STS device.
Palette Object | Description |
---|---|
NI-RFPM Close Calibration |
Closes and commits or aborts the current calibration. This VI does not support the mmWave subsystem. |
NI-RFPM Configure Calibration |
Configures user calibration resources and options. This VI does not support the mmWave subsystem. |
NI-RFPM Fetch Receiver Offset |
Fetches the stored receiver offset for a single frequency, reference level, and path setting at a specified port. When NI-RFPM de-embedding is enabled, the reference level is defined at the DUT reference plane. This VI does not support the mmWave subsystem. |
NI-RFPM Fetch Source Offset With Settings And Settling Time |
Fetches the stored source offset and settling time for a single frequency, power, and path setting for a specified port. When the De-embedding Enabled property is set to TRUE and the De-embedding S2P Path property is set to the correct de-embedding files, the power level is defined at the DUT reference plane. This VI does not support the mmWave subsystem. |
NI-RFPM Init Calibration |
Initializes user or system calibration. This VI does not support the mmWave subsystem. |
NI-RFPM Is Calibration Action Done |
Checks the status of the current calibration action, and returns an estimate of completion progress as a percentage. This VI does not support the mmWave subsystem. |
NI-RFPM Load Calibration and Configuration |
Loads calibration and sweep setting data from a file. This VI does not support the mmWave subsystem. |
NI-RFPM Perform Calibration Action |
Performs one calibration action. This VI does not support the mmWave subsystem. |
NI-RFPM Perform System Calibration |
Performs a system calibration. This VI does not support the mmWave subsystem. |
NI-RFPM Read Available User Calibration Information |
Reads the available user calibration sweep name and port list, as well as date, time, and temperature for the specified sweep type. This VI does not support the mmWave subsystem. |
NI-RFPM Read System Calibration Information |
Returns information about what ports are calibrated, as well as date, time, and temperature, for the system calibration. This VI does not support the mmWave subsystem. |
NI-RFPM Save Calibration and Configuration |
Saves the current user calibration and configuration data. This VI does not support the mmWave subsystem. |
NI-RFPM Wait Calibration Action Done |
Waits for the last user calibration action to complete. If the calibration action does not complete before the specified timeout, this VI returns a timeout error. This VI does not support the mmWave subsystem. |
NI-RFPM Is System Calibration Valid |
Notifies the user if their system calibration is still valid. To be valid, a system calibration must be within the recommended calibration interval and the temperature of the VST must be near the temperature of the calibration. This VI does not support the mmWave subsystem. |
NI-RFPM Get System Calibration Recommended Interval |
Returns the number of months for which a system calibration is valid. This VI does not support the mmWave subsystem. |