Why Is the ACCESS LED Off When the Chassis Is On?
The LEDs may not light until the module has been configured in MAX. Before proceeding, verify that the NI 6544/6545/6547/6548 appears in MAX.
Notice Apply external signals only while the NI 6544/6545/6547/6548 is powered on. Applying external signals while the module is powered off may cause damage.
- Disconnect any signals from the module front panels.
- Power off the chassis.
- Remove the module from the chassis and inspect it for damage. Do not reinstall a damaged module.
- Install the module in a different chassis slot from which you removed it.
-
Power on the chassis.
Note If you are using a PC with a device for PXI remote control system, power on the chassis before powering on the computer.
- Verify that the module appears in MAX.