Configure RFSG to RFmx Trigger (Automatic Routing) (Pulse) VI
- Updated2024-12-03
- 2 minute(s) read
Configures the pulse trigger used for the synchronization. When the RF mode is Pulsed CW, this method uses dynamic routing to set the RFSG Pulse Trigger Output as the input to the RFmx Trigger using an available PXI backplane trigger line. When the RF mode is CW, this method does not export the RFSG Pulse Trigger or configure a RFmx Trigger. In Pulsed CW mode, RFSG exports the pulse trigger at the start of each pulse. In CW RF mode, no trigger is exported and this setting is ignored. RFmx waits for the measure trigger before taking each measurement.

Inputs/Outputs
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
RFmx Trigger Delay (s)
—
Specifies the time, in seconds, RFmx waits after receiving a reference trigger before taking a measurement. The default value is 0.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
error out
—
Error information. This output provides standard error out functionality. |
PAE Reference In
—
RFmx Trigger Delay (s)
—
error in
—
PAE Reference Out
—
error out
—