Short Name: ClockVolt.Low

Property of niHSDIO

Specifies the voltage below which a clock is considered logic low. The value for this property applies to the STROBE terminal in acquisition sessions and the DDC CLK OUT terminal in generation sessions.

Note  Only NI 6555/6556 devices support this property.

Valid values range from –2 to 7, depending on the range selected with the Clock Voltage Range property.

The default value is 0 V for generation and 1.6 V for acquisition.

Units are volts.

Remarks

The following table lists the characteristics of this property.

Datatype fD
PermissionsRead/Write
High-level VIs N/A
Channel-based No
ResettableNo