1250103 | ViReal64 | R/W | Channel | None | niFgen_ConfigureStandardWaveform |
Description
Controls the DC offset of the standard waveform that the signal generator produces. This value is the offset at the output terminal. The value is the offset from ground to the center of the waveform that you specify with the waveform parameter of the niFgen_ConfigureStandardWaveform function.
For example, to configure a waveform with an amplitude of 10.00 V to range from 0.00 V to +10.00 V, set this attribute to 5.00 V.
Units: volts
Default Value: None