Source:Advanced:Compliance Limit Symmetry
- Updated2025-10-06
- 1 minute(s) read
Specifies whether compliance limits for current generation and voltage generation for the device are applied symmetrically about 0 V and 0 A or asymmetrically with respect to 0 V and 0 A.
When set to Symmetric , voltage limits and current limits are set using a single property with a positive value. The resulting range is bounded by this positive value and its opposite.
When set to Asymmetric , you must separately set a limit high and a limit low using distinct properties.
For asymmetric limits, the range bounded by the limit high and limit low must include zero.
Default Value: Symmetric
Remarks
The following table lists the characteristics of this property.
| Short Name | Compliance Limit Symmetry |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Channel-based | Yes |
| Instrument-based | No |
| Resettable | No |
| Symmetric | 0 | Compliance limits are specified symmetrically about 0. |
| Asymmetric | 1 | Compliance limits can be specified asymmetrically with respect to 0. |