The following table shows which VIs are supported by NI-DCPower devices. A indicates that the device supports the VI; an indicates that the device does not support the VI.

VI PXIe-4135
niDCPower Abort With Channels VI[3]
niDCPower Cal Adjust AC Flatness VI
niDCPower Cal Adjust Current Limit VI
niDCPower Cal Adjust Current Measurement VI
niDCPower Cal Adjust Internal Reference VI
niDCPower Cal Adjust Output Resistance VI
niDCPower Cal Adjust Residual Current Offset VI
niDCPower Cal Adjust Residual Voltage Offset VI
niDCPower Cal Adjust Voltage Level VI
niDCPower Cal Adjust Voltage Measurement VI
niDCPower Cal Begin AC Flatness VI
niDCPower Cal Config AC Flatness VI
niDCPower Cal End AC Flatness VI
niDCPower Cal Self Calibrate VI
niDCPower Change Ext Cal Password VI
niDCPower Clear Interchange Warnings VI
niDCPower Clear Latched Output Cutoff State VI
niDCPower Close VI
niDCPower Close External Calibration VI
niDCPower Commit With Channels VI[3]
niDCPower Configure Aperture Time VI
niDCPower Configure Auto Zero VI
niDCPower Configure Current Level VI
niDCPower Configure Current Level Range VI
niDCPower Configure Current Limit VI
niDCPower Configure Current Limit Range VI
niDCPower Configure LCR Compensation VI
niDCPower Configure LCR Custom Cable Compensation VI
niDCPower Configure Output Enabled VI
niDCPower Configure Output Function VI
niDCPower Configure Output Resistance VI [1]
niDCPower Configure Power Line Frequency VI
niDCPower Configure Pulse Bias Current Level VI
niDCPower Configure Pulse Bias Current Limit VI
niDCPower Configure Pulse Bias Voltage Level VI
niDCPower Configure Pulse Bias Voltage Limit VI
niDCPower Configure Pulse Current Level VI
niDCPower Configure Pulse Current Level Range VI
niDCPower Configure Pulse Current Limit VI
niDCPower Configure Pulse Current Limit Range VI
niDCPower Configure Pulse Voltage Level VI
niDCPower Configure Pulse Voltage Level Range VI
niDCPower Configure Pulse Voltage Limit VI
niDCPower Configure Pulse Voltage Limit Range VI
niDCPower Configure Sense VI
niDCPower Configure Source Mode With Channels VI[3]
niDCPower Configure Trigger With Channels (Poly) VI[3]
niDCPower Configure Voltage Level VI
niDCPower Configure Voltage Level Range VI
niDCPower Configure Voltage Limit VI
niDCPower Configure Voltage Limit Range VI
niDCPower Connect Internal Reference VI
niDCPower Create Advanced Sequence With Channels VI[3]
niDCPower Create Advanced Sequence Step With Channels VI[3]
niDCPower Create Advanced Sequence Commit Step With Channels VI
niDCPower Delete Advanced Sequence With Channels VI[3]
niDCPower Disable VI
niDCPower Export Attribute Configuration (Poly) VI
niDCPower Export Signal With Channels VI[3]
niDCPower Fetch Multiple VI
niDCPower Fetch Multiple LCR VI
niDCPower Get Cal User Defined Info VI
niDCPower Get Cal User Defined Info Max Size VI
niDCPower Get Channel Name (Poly) VI
niDCPower Get Ext Cal Last Date And Time VI
niDCPower Get Ext Cal Last Temp VI
niDCPower Get Ext Cal Recommended Interval VI
niDCPower Get LCR Compensation Last Date And Time VI
niDCPower Get LCR Compensation Data VI
niDCPower Get LCR Custom Cable Compensation Data VI
niDCPower Get Next Coercion Record VI
niDCPower Get Next Interchange Warning VI
niDCPower Get Self Cal Last Date And Time VI
niDCPower Get Self Cal Last Temp VI
niDCPower Import Attribute Configuration (Poly) VI
niDCPower Initialize External Calibration VI
niDCPower Initialize With Independent Channels VI[2]
niDCPower Initiate With Channels VI[3]
niDCPower Measure VI
niDCPower Measure Multiple VI
niDCPower Measure Multiple LCR VI
niDCPower Perform LCR Load Compensation VI
niDCPower Perform LCR Open Compensation VI
niDCPower Perform LCR Open Custom Cable Compensation VI
niDCPower Perform LCR Short Compensation VI
niDCPower Perform LCR Short Custom Cable Compensation VI
niDCPower Property Node VI
niDCPower Query In Compliance VI
niDCPower Query Latched Output Cutoff State VI
niDCPower Query Max Current Limit VI
niDCPower Query Max Voltage Level VI
niDCPower Query Min Current Limit VI
niDCPower Query Output State VI
niDCPower Read Current Temperature VI
niDCPower Reset With Channels VI[3]
niDCPower Reset Device VI
niDCPower Reset Interchange Check VI
niDCPower Reset with Defaults VI
niDCPower Revision Query VI
niDCPower Self Test VI
niDCPower Send Software Edge Trigger With Channels VI[3]
niDCPower Set Cal User Defined Info VI
niDCPower Set Sequence VI
niDCPower Wait For Event With Channels VI[3]
1 PXIe-4135, PXIe-4137/4139/4141/4143/4145 only. 2 The deprecated niDCPower Initialize With Channels, Initialize With Options, and Initialize VIs are supported but not recommended. 3 The deprecated, not-channel-based version of this VI is supported but not recommended.

1 PXIe-4135, PXIe-4137/4139/4141/4143/4145 only.

2 The deprecated niDCPower Initialize With Channels, Initialize With Options, and Initialize VIs are supported but not recommended.

3 The deprecated, not-channel-based version of this VI is supported but not recommended.