NI-DCPower .NET fx45 API Reference

Table of Contents

DCPowerOutputSourceOutputCutoff.VoltageMeasureLimitLow Property

  • Updated2024-01-04
  • 2 minute(s) read
DCPowerOutputSourceOutputCutoff.VoltageMeasureLimitLow Property

DCPowerOutputSourceOutputCutoffVoltageMeasureLimitLow Property

Specifies a low limit voltage value, in volts, for output cutoff. If the measured voltage falls below this limit, the output is disconnected.

Namespace:  NationalInstruments.ModularInstruments.NIDCPower
Assembly:  NationalInstruments.ModularInstruments.NIDCPower.Fx45 (in NationalInstruments.ModularInstruments.NIDCPower.Fx45.dll) Version: 2023

Syntax

public double VoltageMeasureLimitLow { get; set; }
Public Property VoltageMeasureLimitLow As Double
	Get
	Set

Property Value

Type: Double
Represents a low voltage threshold for output cutoff.

Remarks

To find out whether an output has fallen below this limit, call the QueryLatchedOutputCutoffState(String, DCPowerOutputCutoffReason) method with OutputCutoffReasonVoltageMeasureLow as the outputCutoffReason.

Note Note
NI-DCPower uses the terms "source" and "output". However, while sinking with electronic loads and SMUs these correspond to "sinking" and "input", respectively.
Note Note
This property is not supported by all instruments. Refer to the Supported Properties by Device topic in the NI DC Power Supplies and SMUs Help for information about supported instruments.