DCPowerOutputLCR Properties
- Updated2024-01-04
- 4 minute(s) read

DCPowerOutputLCR Properties
The DCPowerOutputLCR type exposes the following members.
Properties
Name | Description | |
---|---|---|
![]() | Advanced |
Gets the DCPowerOutputLCRAdvanced sub-object that is used to configure NI-DCPower LCR advanced output.
|
![]() | AutomaticLevelControl |
Specifies whether the channel actively attempts to maintain a constant test voltage or current across the DUT for LCR measurements.
The use of voltage or current depends on the test signal you configure with the StimulusFunction property.
|
![]() | Compensation |
Gets the DCPowerOutputLCRCompensation sub-object that is used to configure NI-DCPower LCR measurement compensation.
|
![]() | CurrentAmplitude |
Specifies the amplitude, in A RMS, of the AC current test signal applied to the DUT for LCR measurements.
|
![]() | CustomMeasurementTime |
Specifies the LCR measurement aperture time for a channel, in seconds, when the MeasurementTime property is set to Custom.
|
![]() | DCBiasAutomaticLevelControl |
Specifies whether the channel actively maintains a constant DC bias voltage or current across the DUT for LCR measurements.
|
![]() | DCBiasCurrentLevel |
Specifies the DC bias current level, in amperes, when the DCBiasSource is set to Current.
|
![]() | DCBiasSource |
Specifies how to apply DC bias for LCR measurements.
|
![]() | DCBiasVoltageLevel |
Specifies the DC bias voltage level, in volts, when the DCBiasSource is set to Voltage.
|
![]() | Frequency |
Specifies the frequency of the AC test signal applied to the DUT for LCR measurements.
|
![]() | ImpedanceAutoRange |
Defines whether an instrument in LCR mode automatically selects the best impedance range for each given LCR measurement.
|
![]() | ImpedanceRange |
Specifies the impedance range the channel uses for LCR measurements.
|
![]() | ImpedanceRangeSource |
Specifies how the impedance range for LCR measurements is determined.
|
![]() | LoadCapacitance |
Specifies the load capacitance, in farads and assuming a series model, of the DUT in order to compute the impedance range when the ImpedanceRangeSource is set to Load Configuration.
|
![]() | LoadInductance |
Specifies the load inductance, in henrys and assuming a series model, of the DUT in order to compute the impedance range when the ImpedanceRangeSource is set to Load Configuration.
|
![]() | LoadResistance |
Specifies the load resistance, in ohms and assuming a series model, of the DUT in order to compute the impedance range when the ImpedanceRangeSource is set to Load Configuration.
|
![]() | MeasurementTime |
Selects a general aperture time profile for LCR measurements.
|
![]() | SourceDelayMode |
For instruments in LCR mode, determines whether NI-DCPower automatically calculates and applies the source delay or applies a source delay you set manually.
|
![]() | StimulusFunction |
Specifies the type of test signal to apply to the DUT for LCR measurements.
|
![]() | VoltageAmplitude |
Specifies the amplitude, in V RMS, of the AC voltage test signal applied to the DUT for LCR measurements.
|