DCPowerOutputSourcePulseCurrent.CurrentLevelRange Property
- Updated2024-01-04
- 2 minute(s) read

DCPowerOutputSourcePulseCurrentCurrentLevelRange Property
Gets or sets the pulse current level range, in amperes, for the specified channel(s).
The range defines the valid values to which you can set the pulse current level and pulse bias current level.
Namespace: NationalInstruments.ModularInstruments.NIDCPower
Assembly: NationalInstruments.ModularInstruments.NIDCPower.Fx40 (in NationalInstruments.ModularInstruments.NIDCPower.Fx40.dll) Version: 2023
Syntax
public double CurrentLevelRange { get; set; }
Public Property CurrentLevelRange As Double Get Set
Property Value
Type: DoubleRefer to the Ranges topic in the NI DC Power Supplies and SMUs Help or to the instrument specifications for information about valid ranges.
Remarks
This property is applicable only if the DCPowerSourceOutputFunction property is set to PulseCurrent.
![]() |
---|
A channel must be enabled for the specified current limit to take effect. Refer to the Enabled property for more information about enabling the channel. This property is not supported by all instruments. Refer to the Supported Properties by Device topic in the NI DC Power Supplies and SMUs Help for information about supported instruments. |