DCPowerMeasurement.ClearLatchedOutputCutoffState Method
- Updated2024-01-04
- 2 minute(s) read

DCPowerMeasurementClearLatchedOutputCutoffState Method
Clears the state of an output cutoff that was engaged.
Namespace: NationalInstruments.ModularInstruments.NIDCPower
Assembly: NationalInstruments.ModularInstruments.NIDCPower.Fx40 (in NationalInstruments.ModularInstruments.NIDCPower.Fx40.dll) Version: 2023
Syntax
public void ClearLatchedOutputCutoffState( string channelString, DCPowerOutputCutoffReason outputCutoffReason )
Public Sub ClearLatchedOutputCutoffState ( channelString As String, outputCutoffReason As DCPowerOutputCutoffReason )
Parameters
- channelString
- Type: SystemString
Specifies the output channels to query. Specify the channel(s) using the form PXI1Slot3/0,PXI1Slot3/2-3,PXI1Slot4/2-3 or PXI1Slot3/0,PXI1Slot3/2:3,PXI1Slot4/2:3, where PXI1Slot3 and PXI1Slot4 are instrument resource names and 0, 2, and 3 are channels. If you do not provide channel(s), all channels in the session are used. - outputCutoffReason
- Type: NationalInstruments.ModularInstruments.NIDCPowerDCPowerOutputCutoffReason
Specifies the reasons for which to clear the output cutoff state.
Remarks
To clear the state for all output cutoff reasons, use OutputCutoffReasonAll.
![]() |
---|
NI-DCPower uses the terms "source" and "output". However, while sinking with electronic loads and SMUs these correspond to "sinking" and "input", respectively. |
![]() |
---|