NI-DCPower C Function Reference Help

NIDCPOWER_ATTR_SEQUENCE_ENGINE_DONE_EVENT_PULSE_WIDTH

  • Updated2023-04-15
  • 1 minute(s) read

Specific Attribute

Numeric Value Data
type
Access Applies to Coercion High-Level Functions
1150049 ViReal64 R/W Channel Yes N/A

Description

Specifies the width of the Sequence Engine Done event, in seconds.

The minimum event pulse width value for PXI devices is 150 ns, and the minimum event pulse width value for PXI Express devices is 250 ns.

The maximum event pulse width value for all devices is 1.6 microseconds.

Note Note This attribute is not supported by all devices. Refer to Supported Attributes by Device for information about supported devices.
Note Note  To specify a channel name when accessing this attribute, you must first initialize the session using the niDCPower_InitializeWithIndependentChannels function.

Valid Values: 1.5e-7 to 1.5e-6 seconds

Default Value: The default value for PXI Express devices is 250 ns.