NIDCPOWER_ATTR_PULSE_BIAS_CURRENT_LEVEL
- Updated2023-04-15
- 1 minute(s) read
Specific Attribute
Numeric Value | Data type |
Access | Applies to | Coercion | High-Level Functions |
---|---|---|---|---|---|
1150088 | ViReal64 | R/W | Channel | None | niDCPower_ConfigurePulseBiasCurrentLevel |
Description
Specifies the pulse bias current level, in amps, that the device attempts to generate on the specified channel(s) during the off phase of a pulse.
This attribute is applicable only if the NIDCPOWER_ATTR_OUTPUT_FUNCTION attribute is set to NIDCPOWER_VAL_PULSE_CURRENT.
![]() |
Note The channel must be enabled for the specified current level to take effect. Refer to the NIDCPOWER_ATTR_OUTPUT_ENABLED attribute for more information about enabling the output channel. |
![]() |
Note This attribute is not supported by all devices. Refer to Supported Attributes by Device for information about supported devices. |
Valid Values: The valid values for this attribute are defined by the values you specify for the NIDCPOWER_ATTR_PULSE_CURRENT_LEVEL_RANGE attribute.