NI-DCPower C Function Reference Help

niDCPower_QueryInCompliance

  • Updated2023-04-15
  • 1 minute(s) read

ViStatus niDCPower_QueryInCompliance(ViSession vi, ViConstString channelName, ViBoolean *inCompliance);

Purpose

Queries the specified output channel to determine if it is operating at the compliance limit.

The compliance limit is the current limit when the output function is set to NIDCPOWER_VAL_DC_VOLTAGE. If the output is operating at the compliance limit, the output reaches the current limit before the desired voltage level. Refer to the niDCPower_ConfigureOutputFunction function and the niDCPower_ConfigureCurrentLimit function for more information about output function and current limit, respectively.

The compliance limit is the voltage limit when the output function is set to NIDCPOWER_VAL_DC_CURRENT. If the output is operating at the compliance limit, the output reaches the voltage limit before the desired current level. Refer to the niDCPower_ConfigureOutputFunction function and the niDCPower_ConfigureVoltageLimit function for more information about output function and voltage limit, respectively.

Related Topics:

Compliance

Parameters

Input
Name Type Description
vi ViSession Identifies a particular instrument session. vi is obtained from the niDCPower_InitializeWithIndependentChannels function.
channelName ViConstString Specifies the output channel to query. Compliance status can only be queried for one channel at a time.

Specify the channel using the form PXI1Slot3/0, where PXI1Slot3 is the instrument resource name and 0 is the channel.

Output
Name Type Description
inCompliance ViBoolean* Returns whether the specified output channel is in compliance.

Return Value

Name Type Description
StatusViStatusReports the status of this operation. To obtain a text description of the status code, call the niDCPower_error_message function. To obtain additional information concerning the error condition, call the niDCPower_GetError function.