ViStatus niDCPower_DisableStartTriggerWithChannels(ViSession vi);

Purpose

Disables the Start trigger. The specified channel(s) do not wait for a Start trigger when starting generation or acquisition.

This function is necessary only if you configured a Start trigger in the past and now want to disable it.

Note Note  This function is not supported on all devices. Refer to Supported Functions by Device for more information about supported devices.

Parameters

Input
Name Type Description
vi ViSession Identifies a particular instrument session. vi is obtained from the niDCPower_InitializeWithIndependentChannels function.
channelName ViConstString Specifies the channel(s) to use. Specify the channel(s) using the form PXI1Slot3/0,PXI1Slot3/2-3,PXI1Slot4/2-3 or PXI1Slot3/0,PXI1Slot3/2:3,PXI1Slot4/2:3, where PXI1Slot3 and PXI1Slot4 are instrument resource names and 0, 2, and 3 are channels.

If you pass "" for this control, all channels in the session are used.

Return Value

Name Type Description
StatusViStatusReports the status of this operation. To obtain a text description of the status code, call the niDCPower_error_message function. To obtain additional information concerning the error condition, call the niDCPower_GetError function.