Analog Input:Strain:Strain Gage:Configuration
- Updated2025-07-28
- 1 minute(s) read
Specifies the bridge configuration of the strain gages.
Remarks
The following table lists the characteristics of this property.
| Short Name | AI.StrainGage.Cfg |
| Data type | ![]() |
| Permissions | Read/Write |
| Resettable | True |
| Settable While Task Is Running | device-specific |
| Available in Run-Time Engine | True |
| Full Bridge I | 10183 | Four active gages with two pairs subjected to equal and opposite strains. |
| Full Bridge II | 10184 | Four active gages with two aligned with maximum principal strain and two Poisson gages in adjacent arms. |
| Full Bridge III | 10185 | Four active gages with two aligned with maximum principal strain and two Poisson gages in opposite arms. |
| Half Bridge I | 10188 | Two active gages with one aligned with maximum principal strain and one Poisson gage. |
| Half Bridge II | 10189 | Two active gages with equal and opposite strains. |
| Quarter Bridge I | 10271 | Single active gage. |
| Quarter Bridge II | 10272 | Single active gage and one dummy gage. |