NI 9474 (Scan Interface)
- Updated2025-04-03
- 1 minute(s) read
Module I/O Variables
To use I/O from this module in a VI, drag and drop I/O variables from the Project Explorer window to the block diagram of the VI. The I/O variables write Boolean values to the channels.
Module Channels
The NI 9474 has the following channels.
Channel | Description |
---|---|
DOx | Digital output channel x, where x is the number of the channel. For the NI 9474, x is 0 to 7. |
C Series Module Properties Dialog Box
Use this dialog box to configure the NI 9474. Right-click the NI 9474 in the Project Explorer window and select Properties to display this dialog box. You can configure the following options.
- Name—Specifies the name of the C Series module, which appears in the Project Explorer window. LabVIEW assigns a default name to the module based on the slot number. You can use this field to give the module a descriptive name.
- Module Type—Specifies the type of C Series module. You cannot change this value.
- Location—Specifies a slot in the chassis for the C Series module.
Specialty Digital Configuration
Use the Specialty Digital Configuration page of the C Series Module Properties dialog box to configure channels of this module for counter-driven output or pulse-width modulation output.