NI Bluetooth Analysis Toolkit

niBT SA Select Measurement VI

  • Updated2023-02-21
  • 4 minute(s) read

Specifies the measurements that you want to enable. To select a single measurement, use the Single Measurement instance. To select multiple measurements, use the Multiple Measurements instance.

niBT SA Select Single Measurement

Enables the measurement that you specify in the measurement parameter and disables all other measurements.

niBT SA Select Single Measurement

crn.gif

niBT SA session specifies the niBT SA session refnum. Use this parameter to configure the behavior and operation of the appropriate NI Bluetooth Analysis Toolkit VI that accepts the niBT SA session refnum at its input.

cenum.gif

measurement specifies the measurement to perform. You can specify one of the following measurements.

TxP (0)

Enables TxP measurements.

DF1 (1)

Enables DF1 measurements.

DF2 (2)

Enables DF2 measurements.

CFO (3)

Enables carrier frequency offset (CFO) measurements.

DEVM (4)

Enables differential error vector magnitude (DEVM) measurements.

BER (5)

Enables bit error rate (BER) measurements.

TxSpectrum (6)

Enables transmit spectrum (TxSpectrum) measurements.

ACP (7)

Enables adjacent channel power (ACP) measurements.

EDRInBandEmission (8)

Enables EDRInBandEmission measurements.

LEInBandEmission (9)

Enables LEInBandEmission measurements.

PER (10)

Enables PER measurements.

cbool.gif

enable traces? specifies whether to enable traces for the selected measurement.

cerrcodeclst.gif

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

irn.gif

niBT SA session out returns the niBT SA session refnum. Use this reference as the session input to subsequent VIs.

Note  Close the niBT SA session refnum using the niBT SA Close Session VI before the VI completes execution to avoid possible memory leak issues.
ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

niBT SA Select Multiple Measurements

Enables all the measurements that you specify in the measurements parameter and disables all other measurements.

niBT SA Select Multiple Measurements

crn.gif

niBT SA session specifies the niBT SA session refnum. Use this parameter to configure the behavior and operation of the appropriate NI Bluetooth Analysis Toolkit VI that accepts the niBT SA session refnum at its input.

c1denum.gif

measurements specifies the measurements to perform. You can specify multiple measurements from the following measurements.

TxP (0)

Enables TxP measurements.

DF1 (1)

Enables DF1 measurements.

DF2 (2)

Enables DF2 measurements.

CFO (3)

Enables CFO measurements.

DEVM (4)

Enables DEVM measurements.

BER (5)

Enables BER measurements.

TxSpectrum (6)

Enables TxSpectrum measurements.

ACP (7)

Enables ACP measurements.

EDRInBandEmission (8)

Enables EDRInBandEmission measurements.

LEInBandEmission (9)

Enables LEInBandEmission measurements.

PER (10)

Enables PER measurements.

cbool.gif

enable traces? specifies whether to enable traces for the selected measurements.

cerrcodeclst.gif

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

irn.gif

niBT SA session out returns the niBT SA session refnum. Use this reference as the session input to subsequent VIs.

Note  Close the niBT SA session refnum using the niBT SA Close Session VI before the VI completes execution to avoid possible memory leak issues.
ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

Log in to get a better experience