NI 6585/6585B Specifications

FlexRIO Documentation

Table 1. FlexRIO Documentation Locations and Descriptions
Document Location Description
Getting started guide for your FlexRIO FPGA module or Controller for FlexRIO Available from the Start menu and at ni.com/manuals. Contains installation instructions for your FlexRIO system.
Specifications document for your FlexRIO FPGA module or Controller for FlexRIO Available from the Start menu and at ni.com/manuals. Contains specifications for your FlexRIO FPGA module or Controller for FlexRIO.
Getting started guide for your adapter module Available from the Start menu and at ni.com/manuals. Contains signal information, examples, and CLIP details for your adapter module.
Specifications document for your adapter module Available from the Start menu and at ni.com/manuals. Contains specifications for your adapter module.
LabVIEW FPGA Module Help Embedded in LabVIEW Help and at ni.com/manuals. Contains information about the basic functionality of the LabVIEW FPGA Module.
Real-Time Module Help Embedded in LabVIEW Help and at ni.com/manuals. Contains information about real-time programming concepts, step-by-step instructions for using LabVIEW with the Real-Time Module, reference information about Real-Time Module VIs and functions, and information about LabVIEW features on real-time operating systems.
FlexRIO Help Available from the Start menu and at ni.com/manuals. Contains information about the FPGA module front panel connectors and I/O, controller for FlexRIO front panel connectors and I/O, programming instructions, and adapter module component-level IP (CLIP).
LabVIEW Examples Available in NI Example Finder. In LabVIEW, click Help » Find Examples » Hardware Input and Output » FlexRIO. Contains examples of how to run FPGA VIs and Host VIs on your device.
IPNet Located at ni.com/ipnet. Contains LabVIEW FPGA functions and intellectual property to share.
FlexRIO product page Located at ni.com/flexrio. Contains product information and data sheets for FlexRIO devices.

NI 6585/6585B Pinout

Use the pinout to connect to terminals on the NI 6585/6585B.

Figure 1. NI 6585/6585B Connector Pinout


Note DIO <0..15>+/-, PFI <0..4>+/-, and DDC CLOCK OUT appear on both connectors, DDCA and DDCB.
Note PFI <0> can be used as an IO port. You can modify the CLIP for the NI 6585B to expose the signal as PFI <0>.
Table 2. Signal Descriptions
Signal Name Pin(s) Signal Type Signal Description
GLOBAL CLOCK 0+ 26 on DDCA Clock Input terminal for the external clock source, which can be used for dynamic acquisition or generation.
GLOBAL CLOCK 0- 27 on DDCA
GLOBAL CLOCK 1+ 26 on DDCB
GLOBAL CLOCK 1- 27 on DDCB
DIO <0..15>+ 2, 5, 8 ,11 ,14, 17, 20, 23, 37, 40, 43, 46, 49, 52, 55 , 58 Data Positive terminal of LVDS digital I/O data channels 0 through 15.
DIO <0..15>- 3, 6, 9, 12, 15, 18, 21, 24, 38, 41, 44, 47, 50, 53, 56, 59 Data Negative terminal of LVDS digital I/O data channels 0 through 15.
DDC CLOCK OUT+/PFI 0+ 61 Clock/Data Positive output terminal for the exported Sample clock/Positive Programmable Function Interface terminal 0
DDC CLOCK OUT-/PFI 0- 62 Clock/Data Negative output terminal for the exported Sample clock/Negative Programmable Function Interface terminal 0
PFI <1..4>+ 29, 64, 32, 67 Data Positive terminal of the Programmable Function Interface LVDS digital I/O channels 1 through 4.
PFI <1..4>- 30, 65, 33, 68 Data Negative terminal of the Programmable Function Interface LVDS digital I/O channels 1 through 4.
GND 1, 4, 7, 10, 13, 16, 19, 22, 25, 28, 31, 34, 35, 36, 39, 42, 45, 48, 51, 54, 57, 60, 63, 66 Ground Ground reference for signals.
Caution To avoid damaging the NI 6585/6585B, disconnect all connected signals before powering down. Connect signals after the adapter module powers on by the FlexRIO FPGA module or Controller for FlexRIO.
Caution Connections that exceed the maximum ratings of connectors on the NI 6585/6585B might damage the device and the chassis. NI is not liable for any damage resulting from such connections.
Table 3. NI 6585/6585B DDCA Connector Signals and FlexRIO FPGA Module Signals
NI 6585/6585B FlexRIO FPGA Module
Connector Signal Name GPIO Out GPIO Out Enable GPIO In
DDCA GLOBAL CLOCK 0 GClk_SE
DIO 0+/- GPIO_30_n GPIO_31 GPIO_31_n
DIO 1+/- GPIO_12_n GPIO_13 GPIO_13_n
DIO 2+/- GPIO_32 GPIO_32_n GPIO_15_n
DIO 3+/- GPIO_14 GPIO_14_n GPIO_15
DIO 4+/- GPIO_27_n GPIO_28 GPIO_28_n
DIO 5+/- GPIO_9_n GPIO_10 GPIO_10_n
DIO 6+/- GPIO_29 GPIO_29_n GPIO_30
DIO 7+/- GPIO_11 GPIO_11_n GPIO_12
DIO 8+/- GPIO_22 GPIO_22_n GPIO_23
DIO 9+/- GPIO_6_n GPIO_7 GPIO_7_n
DIO 10+/- GPIO_26 GPIO_26_n GPIO_27
DIO 11+/- GPIO_8 GPIO_8_n GPIO_9
DIO 12+/- GPIO_19 GPIO_19_n GPIO_20
DIO 13+/- GPIO_3_n GPIO_4 GPIO_4_n
DIO 14+/- GPIO_20_n GPIO_21 GPIO_21_n
DIO 15+/- GPIO_5 GPIO_5_n GPIO_6
DDC CLOCK OUT+/PFI 0+ DDC CLOCK OUT-/PFI 0- GPIO_0 GPIO_0_n GPIO_23_n
PFI 1+/- GPIO_1 GPIO_1_n GPIO_24
PFI 2+/- GPIO_16 GPIO_16_n GPIO_24_n
PFI 3+/- GPIO_17 GPIO_17_n GPIO_25
PFI 4+/- GPIO_18 GPIO_18_n GPIO_25_n
Table 4. NI 6585/6585B DDCB Connector Signals and FlexRIO FPGA Module Signals
NI 6585/6585B FlexRIO FPGA Module
Connector Signal Name GPIO Out GPIO Out Enable GPIO In
DDCB GLOBAL CLOCK 1 GClk_LVDS
DIO 0+/- GPIO_46 GPIO_46_n GPIO_47
DIO 1+/- GPIO_62_n GPIO_63 GPIO_63_n
DIO 2+/- GPIO_47_n GPIO_48 GPIO_48_n
DIO 3+/- GPIO_64 GPIO_64_n GPIO_65
DIO 4+/- GPIO_43 GPIO_43_n GPIO_44
DIO 5+/- GPIO_59_n GPIO_60 GPIO_60_n
DIO 6+/- GPIO_44_n GPIO_45 GPIO_45_n
DIO 7+/- GPIO_61 GPIO_61_n GPIO_62
DIO 8+/- GPIO_39 GPIO_39_n GPIO_40
DIO 9+/- GPIO_54 GPIO_54_n GPIO_55
DIO 10+/- GPIO_40_n GPIO_41 GPIO_41_n
DIO 11+/- GPIO_55_n GPIO_56 GPIO_56_n
DIO 12+/- GPIO_36 GPIO_36_n GPIO_37
DIO 13+/- GPIO_51 GPIO_51_n GPIO_52
DIO 14+/- GPIO_37_n GPIO_38 GPIO_38_n
DIO 15+/- GPIO_52_n GPIO_53 GPIO_53_n
DDC CLOCK OUT+/PFI 0+ DDC CLOCK OUT-/PFI 0- GPIO_49 GPIO_49_n GPIO_57
PFI 1+/- GPIO_50 GPIO_50_n GPIO_57_n
PFI 2+/- GPIO_33 GPIO_33_n GPIO_58
PFI 3+/- GPIO_34 GPIO_34_n GPIO_58_n
PFI 4+/- GPIO_35 GPIO_35_n GPIO_59

Channel Specifications per Connector

Number of DDC connectors

2, DDCA and DDCB

Number of digital I/O channels

42 total (16 data, 5 PFI per DDC connector)

Direction control of data channels

Per channel

Power up state

Drivers disabled, 100 Ω differential impedance

Acquisition

Acquisition voltage levels

Differential voltage threshold

±50 mV

Voltage range

0 V min, 2.4 V max

Input impedance

100 Ω differential nominal

Maximum data rate

200 MBit/s single rate (SDR); 300 MBit/s double data rate (DDR)

Generation

Table 5. Generation voltage levels (50 Ω LVDS load)
Minimum Maximum
Differential 247 mV 454 mV
Common Mode 1.125 V 1.375 V
Note Generation expects 100 Ω termination at the destination in addition to the 100 Ω input termination of the NI 6585/6585B.

Characteristic impedance

100 Ω differential nominal

Maximum data rate

Single data rate (SDR)

200 MBit/s

Double data rate (DDR)

300 MBit/s

Figure 1. Clock Input (NI 6585 variant)


Figure 1. Clock Input (NI 6585B variant)


* DDCB Global Clock In can only clock DIO on the DDCB connector.

Figure 1. DIO <0..15> Data Channel, PFI <0..4>


Note Applies to each data and PFI channel. CLOCK OUT is the same as PFI 0.

Power

NI PXI-795xR/NI PXIe-796xR

VccoA

315 mA, 1.1 W max

VccoB

315 mA, 1.1 W max

+3.3 V

36 mA, 0.12 W max

NI PXIe-797xR and NI-793xR (NI 6585B only)

Vcco

630 mA, 2.2 W max

Physical

Dimensions

12.9 × 2.0 × 12.1 cm (5.1 × 0.8 × 4.7 in.)

Weight

284 g (10 oz)

Front Panel Connectors

Two 68-pin VHDCI connectors

Environment

Maximum altitude

2,000 m (800 mbar) (at 25 °C ambient temperature)

Pollution Degree

2

Indoor use only.

Operating Environment

Ambient temperature range

0 °C to 55 °C

Relative humidity range

10% to 90%, noncondensing

Storage Environment

Ambient temperature range

-20 °C to 71 °C

Relative humidity range

5% to 95%, noncondensing

Shock and Vibration

Operating shock

30 g peak, half-sine, 11 ms pulse

Random vibration

Operating

5 Hz to 500 Hz, 0.3 g RMS

Nonoperating

5 Hz to 500 Hz, 2.4 g RMS

Compliance and Certifications

Safety Compliance Standards

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

  • IEC 61010-1, EN 61010-1
  • UL 61010-1, CSA C22.2 No. 61010-1
Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
  • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
  • EN 55011 (CISPR 11): Group 1, Class A emissions
  • EN 55022 (CISPR 22): Class A emissions
  • EN 55024 (CISPR 24): Immunity
  • AS/NZS CISPR 11: Group 1, Class A emissions
  • AS/NZS CISPR 22: Class A emissions
  • FCC 47 CFR Part 15B: Class A emissions
  • ICES-001: Class A emissions
Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.
Note For EMC declarations, certifications, and additional information, refer to the Product Certifications and Declarations section.

Product Certifications and Declarations

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

Environmental Management

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

EU and UK Customers
  • Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.
  • 电子信息产品污染控制管理办法(中国RoHS)
  • 中国RoHSNI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)