SVFA Wrap or Unwrap Phase VI
- Updated2025-12-02
- 14 minute(s) read
Owning Palette: Spectrum Extended Measurements VIs
Requires: Sound and Vibration Toolkit
Wraps the phase spectra to the specified range, so that all phase values are coerced to the specified band. You also can use this VI to unwrap phase spectra to eliminate discontinuities with absolute values exceeding 180 degrees = pi radians = 0.5 cycles. Wire data to the phase spectrum in input to determine the polymorphic instance to use or manually select the instance.
Details
| SVFA Wrap or Unwrap Phase (Spectrum) (1 Ch)SVFA Wrap or Unwrap Phase (Spectrum) (N Ch)SVFA Wrap or Unwrap Phase (Spectrum) (NxM)SVFA Wrap or Unwrap Phase (XY Spectrum) (1 Ch)SVFA Wrap or Unwrap Phase (XY Spectrum) (N Ch) |
SVFA Wrap or Unwrap Phase (Spectrum) (1 Ch)
|
phase spectrum in
specifies the frequency spacing and the phase of the spectrum. The units for
phase spectrum in
are specified in
spectrum info
.
|
||||||||||||||||
|
desired wrapping
specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
|
||||||||||||||||
|
custom wrap range
specifies the range for the returned phase spectrum when
desired wrapping
is
Wrap: custom range
. The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter
minimum phase
and
maximum phase
with the same units as
phase spectrum in
.
|
||||||||||||||||
|
spectrum info
specifies the properties of the computed spectrum.
Note
You must wire
spectrum info
when performing extended measurements. Do not modify the
spectrum info
values. If you want to view the information, you can right-click the
spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||||
|
phase spectrum out
returns the phase spectrum wrapped or unwrapped according to the
desired wrapping
.
|
||||||||||||||||
|
unit label returns the selected engineering units. | ||||||||||||||||
|
dup spectrum info
returns
spectrum info
unchanged.
Note
You must wire
dup spectrum info
when performing extended measurements. Do not modify the
dup spectrum info
values. If you want to view the information, you can right-click the
dup spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error out contains error information. This output provides standard error out functionality. |
SVFA Wrap or Unwrap Phase (Spectrum) (N Ch)
|
phase spectra in
specifies the frequency spacing and the phase for each spectrum. The units for
phase spectra in
are specified in
spectrum info
.
|
||||||||||||||||
|
desired wrapping
specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
|
||||||||||||||||
|
custom wrap range
specifies the range for the returned phase spectrum when
desired wrapping
is
Wrap: custom range
. The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter
minimum phase
and
maximum phase
with the same units as
phase spectrum in
.
|
||||||||||||||||
|
spectrum info
specifies the properties of the computed spectrum.
Note
You must wire
spectrum info
when performing extended measurements. Do not modify the
spectrum info
values. If you want to view the information, you can right-click the
spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||||
|
phase spectra out
returns the phase spectra wrapped or unwrapped according to the
desired wrapping
.
|
||||||||||||||||
|
unit labels returns the selected engineering units for each channel. | ||||||||||||||||
|
dup spectrum info
returns
spectrum info
unchanged.
Note
You must wire
dup spectrum info
when performing extended measurements. Do not modify the
dup spectrum info
values. If you want to view the information, you can create a custom probe.
|
||||||||||||||||
|
error out contains error information. This output provides standard error out functionality. |
SVFA Wrap or Unwrap Phase (Spectrum) (NxM)
|
phase spectra in
specifies the frequency spacing and the phase for each spectrum. The units for
phase spectra in
are specified in
spectrum info
.
|
||||||||||||||||
|
desired wrapping
specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
|
||||||||||||||||
|
custom wrap range
specifies the range for the returned phase spectrum when
desired wrapping
is
Wrap: custom range
. The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter
minimum phase
and
maximum phase
with the same units as
phase spectrum in
.
|
||||||||||||||||
|
spectrum info
specifies the properties of the computed spectrum.
Note
You must wire
spectrum info
when performing extended measurements. Do not modify the
spectrum info
values. If you want to view the information, you can right-click the
spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||||
|
phase spectra out
returns the phase spectra wrapped or unwrapped according to the
desired wrapping
.
|
||||||||||||||||
|
unit labels returns the selected engineering units for each channel. | ||||||||||||||||
|
dup spectrum info
returns
spectrum info
unchanged.
Note
You must wire
dup spectrum info
when performing extended measurements. Do not modify the
dup spectrum info
values. If you want to view the information, you can create a custom probe.
|
||||||||||||||||
|
error out contains error information. This output provides standard error out functionality. |
SVFA Wrap or Unwrap Phase (XY Spectrum) (1 Ch)
|
phase spectrum in
specifies the abscissa values and the phase of the spectrum. The units for
phase spectrum in
are specified in
spectrum info
.
|
||||||||||||||||
|
desired wrapping
specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
|
||||||||||||||||
|
custom wrap range
specifies the range for the returned phase spectrum when
desired wrapping
is
Wrap: custom range
. The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter
minimum phase
and
maximum phase
with the same units as
phase spectrum in
.
|
||||||||||||||||
|
spectrum info
specifies the properties of the computed spectrum.
Note
You must wire
spectrum info
when performing extended measurements. Do not modify the
spectrum info
values. If you want to view the information, you can right-click the
spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||||
|
phase spectrum out
returns the phase spectrum wrapped or unwrapped according to the
desired wrapping
.
|
||||||||||||||||
|
unit label returns the selected engineering units. | ||||||||||||||||
|
dup spectrum info
returns
spectrum info
unchanged.
Note
You must wire
dup spectrum info
when performing extended measurements. Do not modify the
dup spectrum info
values. If you want to view the information, you can right-click the
dup spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error out contains error information. This output provides standard error out functionality. |
SVFA Wrap or Unwrap Phase (XY Spectrum) (N Ch)
|
phase spectra in
specifies the abscissa values and the phase for each spectrum. The units for
phase spectra in
are specified in
spectrum info
.
|
||||||||||||||||
|
desired wrapping
specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
|
||||||||||||||||
|
custom wrap range
specifies the range for the returned phase spectrum when
desired wrapping
is
Wrap: custom range
. The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter
minimum phase
and
maximum phase
with the same units as
phase spectrum in
.
|
||||||||||||||||
|
spectrum info
specifies the properties of the computed spectrum.
Note
You must wire
spectrum info
when performing extended measurements. Do not modify the
spectrum info
values. If you want to view the information, you can right-click the
spectrum info
wire and select
Custom Probe»Spectrum Info
from the shortcut menu.
|
||||||||||||||||
|
error in describes error conditions that occur before this node runs. This input provides standard error in functionality. | ||||||||||||||||
|
phase spectra out
returns the phase spectra wrapped or unwrapped according to the
desired wrapping
.
|
||||||||||||||||
|
unit labels returns the selected engineering units for each channel. | ||||||||||||||||
|
dup spectrum info
returns
spectrum info
unchanged.
Note
You must wire
dup spectrum info
when performing extended measurements. Do not modify the
dup spectrum info
values. If you want to view the information, you can create a custom probe.
|
||||||||||||||||
|
error out contains error information. This output provides standard error out functionality. |
SVFA Wrap or Unwrap Phase Details
You can use wrapped values for display, because you can restrict the range of phase values to a span of 360 degrees. Unwrapped phase values can show the phase spectrum more clearly in frequency ranges dominated by time delay or resonances.