Wraps the phase spectra to the specified range, so that all phase values are coerced to the specified band. You also can use this VI to unwrap phase spectra to eliminate discontinuities with absolute values exceeding 180 degrees = pi radians = 0.5 cycles. Wire data to the phase spectrum in input to determine the polymorphic instance to use or manually select the instance.

Details

SVFA Wrap or Unwrap Phase (Spectrum) (1 Ch)SVFA Wrap or Unwrap Phase (Spectrum) (N Ch)SVFA Wrap or Unwrap Phase (Spectrum) (NxM)SVFA Wrap or Unwrap Phase (XY Spectrum) (1 Ch)SVFA Wrap or Unwrap Phase (XY Spectrum) (N Ch)

SVFA Wrap or Unwrap Phase (Spectrum) (1 Ch)

phase spectrum in specifies the frequency spacing and the phase of the spectrum. The units for phase spectrum in are specified in spectrum info .
f0 specifies the start frequency, in hertz, of the spectrum.
df specifies the frequency resolution, in hertz, of the spectrum.
phase specifies the phase of the spectrum.
desired wrapping specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
0 No change
1 Unwrap
2 Wrap: –360 to 0
3 Wrap: –270 to 90
4 Wrap: –180 to 180 (default)
5 Wrap: –90 to 270
6 Wrap: 0 to 360
7 Wrap: custom range
custom wrap range specifies the range for the returned phase spectrum when desired wrapping is Wrap: custom range . The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter minimum phase and maximum phase with the same units as phase spectrum in .
minimum phase specifies the minimum phase of the spectrum. The default is –Inf.
maximum phase specifies the maximum phase of the spectrum. The default is Inf.
spectrum info specifies the properties of the computed spectrum.
Note You must wire spectrum info when performing extended measurements. Do not modify the spectrum info values. If you want to view the information, you can right-click the spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
phase spectrum out returns the phase spectrum wrapped or unwrapped according to the desired wrapping .
f0 returns the start frequency, in hertz, of the spectrum.
df returns the frequency resolution, in hertz, of the spectrum.
phase returns the phase of the spectrum.
unit label returns the selected engineering units.
dup spectrum info returns spectrum info unchanged.
Note You must wire dup spectrum info when performing extended measurements. Do not modify the dup spectrum info values. If you want to view the information, you can right-click the dup spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error out contains error information. This output provides standard error out functionality.

SVFA Wrap or Unwrap Phase (Spectrum) (N Ch)

phase spectra in specifies the frequency spacing and the phase for each spectrum. The units for phase spectra in are specified in spectrum info .
f0 specifies the start frequency, in hertz, of the spectrum.
df specifies the frequency resolution, in hertz, of the spectrum.
phase specifies the phase of the spectrum.
desired wrapping specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
0 No change
1 Unwrap
2 Wrap: –360 to 0
3 Wrap: –270 to 90
4 Wrap: –180 to 180 (default)
5 Wrap: –90 to 270
6 Wrap: 0 to 360
7 Wrap: custom range
custom wrap range specifies the range for the returned phase spectrum when desired wrapping is Wrap: custom range . The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter minimum phase and maximum phase with the same units as phase spectrum in .
minimum phase specifies the minimum phase of the spectrum. The default is –Inf.
maximum phase specifies the maximum phase of the spectrum. The default is Inf.
spectrum info specifies the properties of the computed spectrum.
Note You must wire spectrum info when performing extended measurements. Do not modify the spectrum info values. If you want to view the information, you can right-click the spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
phase spectra out returns the phase spectra wrapped or unwrapped according to the desired wrapping .
f0 returns the start frequency, in hertz, of the spectrum.
df returns the frequency resolution, in hertz, of the spectrum.
phase returns the phase of the spectrum.
unit labels returns the selected engineering units for each channel.
dup spectrum info returns spectrum info unchanged.
Note You must wire dup spectrum info when performing extended measurements. Do not modify the dup spectrum info values. If you want to view the information, you can create a custom probe.
error out contains error information. This output provides standard error out functionality.

SVFA Wrap or Unwrap Phase (Spectrum) (NxM)

phase spectra in specifies the frequency spacing and the phase for each spectrum. The units for phase spectra in are specified in spectrum info .
f0 specifies the start frequency, in hertz, of the spectrum.
df specifies the frequency resolution, in hertz, of the spectrum.
phase specifies the phase of the spectrum.
desired wrapping specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
0 No change
1 Unwrap
2 Wrap: –360 to 0
3 Wrap: –270 to 90
4 Wrap: –180 to 180 (default)
5 Wrap: –90 to 270
6 Wrap: 0 to 360
7 Wrap: custom range
custom wrap range specifies the range for the returned phase spectrum when desired wrapping is Wrap: custom range . The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter minimum phase and maximum phase with the same units as phase spectrum in .
minimum phase specifies the minimum phase of the spectrum. The default is –Inf.
maximum phase specifies the maximum phase of the spectrum. The default is Inf.
spectrum info specifies the properties of the computed spectrum.
Note You must wire spectrum info when performing extended measurements. Do not modify the spectrum info values. If you want to view the information, you can right-click the spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
phase spectra out returns the phase spectra wrapped or unwrapped according to the desired wrapping .
f0 returns the start frequency, in hertz, of the spectrum.
df returns the frequency resolution, in hertz, of the spectrum.
phase returns the phase of the spectrum.
unit labels returns the selected engineering units for each channel.
dup spectrum info returns spectrum info unchanged.
Note You must wire dup spectrum info when performing extended measurements. Do not modify the dup spectrum info values. If you want to view the information, you can create a custom probe.
error out contains error information. This output provides standard error out functionality.

SVFA Wrap or Unwrap Phase (XY Spectrum) (1 Ch)

phase spectrum in specifies the abscissa values and the phase of the spectrum. The units for phase spectrum in are specified in spectrum info .
X specifies the abscissa of the phase spectrum.
phase specifies the phase of the spectrum.
desired wrapping specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
0 No change
1 Unwrap
2 Wrap: –360 to 0
3 Wrap: –270 to 90
4 Wrap: –180 to 180 (default)
5 Wrap: –90 to 270
6 Wrap: 0 to 360
7 Wrap: custom range
custom wrap range specifies the range for the returned phase spectrum when desired wrapping is Wrap: custom range . The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter minimum phase and maximum phase with the same units as phase spectrum in .
minimum phase specifies the minimum phase of the spectrum. The default is –Inf.
maximum phase specifies the maximum phase of the spectrum. The default is Inf.
spectrum info specifies the properties of the computed spectrum.
Note You must wire spectrum info when performing extended measurements. Do not modify the spectrum info values. If you want to view the information, you can right-click the spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
phase spectrum out returns the phase spectrum wrapped or unwrapped according to the desired wrapping .
X returns the abscissa of the phase spectrum.
phase returns the phase of the spectrum.
unit label returns the selected engineering units.
dup spectrum info returns spectrum info unchanged.
Note You must wire dup spectrum info when performing extended measurements. Do not modify the dup spectrum info values. If you want to view the information, you can right-click the dup spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error out contains error information. This output provides standard error out functionality.

SVFA Wrap or Unwrap Phase (XY Spectrum) (N Ch)

phase spectra in specifies the abscissa values and the phase for each spectrum. The units for phase spectra in are specified in spectrum info .
X specifies the abscissa of the phase spectrum.
phase specifies the phase of the spectrum.
desired wrapping specifies whether the returned phase wraps to the selected range or unwraps to remove discontinuities in the phase spectrum greater than pi.
0 No change
1 Unwrap
2 Wrap: –360 to 0
3 Wrap: –270 to 90
4 Wrap: –180 to 180 (default)
5 Wrap: –90 to 270
6 Wrap: 0 to 360
7 Wrap: custom range
custom wrap range specifies the range for the returned phase spectrum when desired wrapping is Wrap: custom range . The custom range must span at least 2pi = 360 deg = 1 cycle to guarantee that each phase can be mapped to the desired range. If the custom range is greater than 2pi = 360 deg = 1 cycle, the minimum correction is applied to each phase value to map the value to the desired range. Enter minimum phase and maximum phase with the same units as phase spectrum in .
minimum phase specifies the minimum phase of the spectrum. The default is –Inf.
maximum phase specifies the maximum phase of the spectrum. The default is Inf.
spectrum info specifies the properties of the computed spectrum.
Note You must wire spectrum info when performing extended measurements. Do not modify the spectrum info values. If you want to view the information, you can right-click the spectrum info wire and select Custom Probe»Spectrum Info from the shortcut menu.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
phase spectra out returns the phase spectra wrapped or unwrapped according to the desired wrapping .
f0 returns the start frequency, in hertz, of the spectrum.
df returns the frequency resolution, in hertz, of the spectrum.
phase returns the phase of the spectrum.
unit labels returns the selected engineering units for each channel.
dup spectrum info returns spectrum info unchanged.
Note You must wire dup spectrum info when performing extended measurements. Do not modify the dup spectrum info values. If you want to view the information, you can create a custom probe.
error out contains error information. This output provides standard error out functionality.

SVFA Wrap or Unwrap Phase Details

You can use wrapped values for display, because you can restrict the range of phase values to a span of 360 degrees. Unwrapped phase values can show the phase spectrum more clearly in frequency ranges dominated by time delay or resonances.