DIP Switches
- Updated2025-10-31
- 1 minute(s) read
Verify that the four interlock DIP switches on the rack control unit (RCU) are enabled to ensure proper function of the ETX-1640x safety interlocks.
Refer to the Rack Control Unit section of the ATE Core Configurations Generation 2 User Manual for information about the location and settings of the RCU interlock DIP switches.
Refer to the following table for the default state of the interlock DIP switches in the ETX-1640x system.
| Switch | State | Position |
|---|---|---|
| 1 | Closed | Up |
| 2 | Closed | Up |
| 3 | Open | Down |
| 4 | Closed | Up |
Do not change the state of the RCU interlock DIP switches. Changing the state of the DIP switches compromises the ability of the test rack to deactivate hazardous signals.
To check the state of inputs to the interlock circuit, use the example program that NI provides. The example program can help determine whether the rack believes it is safe to source hazardous voltage. The program can also check whether the interlock circuit is behaving as expected.
Related Information
- Rack Control Unit
- Interlock Circuit
The ETX-1640x includes an interlock circuit that you can configure to prevent devices from outputting hazardous voltage, with the exception of controlled conditions.