Replacing the RM-16061
- Updated2025-10-31
- 2 minute(s) read
NI recommends that you replace the RM-16061 within the ETX-1630x when the switch count on any one of the contactors reaches 1 million cycles.
Note Lifting the RM-16061 requires two people. Ensure
there is enough space near the crate to place the new RM-16061 after lifting it out
of the crate.
Equipment
- Small Phillips head screwdriver
- 3 mm hex socket
- Rack key
- Size 8 wrench
- Small NI screwdriver
- #2 Phillips screwdriver
- Follow all Before Maintenance or Repair procedures.
- Remove the side panel using a 3 mm hex socket.
- Unlock and remove the top door of the rack using your rack key.
-
Remove the access panel below the monitor using a Phillips head
screwdriver.
For additional access, you can open the VPC 9025 fold down panel using a #2 Phillips screwdriver.
-
Locate the RM-16061 directly behind the mass interconnect.
Refer to ETX-1630x Hardware Components for more information.Note Do not remove the mass interconnect.
-
Remove all connections to the RM-16061.
- Mass interconnect side: Use a size 8 wrench to loosen and remove the M5 hex nut and M5 hex bolt at each bus bar connection
- Human-machine interface side:
- Remove all connections, including the top right ground lug
- Remove all captive connections with a small NI screwdriver
- Unplug all other connections
- Using two people, slide the RM-16061 out of the human-machine interface side of the rack and place the RM-16061 on the adjacent table.
- Install a new RM-16061 into the rack.
Related Information
- ETX-1630x Hardware Components
The ETX-1630x is comprised of the following hardware components.