It is critical to maintain isolation between the outputs of the high-power supply, the pulser bias supply, and ground.
You must isolate the following pins on the mass interconnect.
| Mass Interconnect Slot | Pin |
|---|---|
| J9 | A4 |
| A8 | |
| B4 | |
| B8 | |
| J11 | A0 |
| A1[1]1 After you build a path in the pulser, you can ground reference the pins in that path as long as the path remains intact. The adapter design must leave these pins floating to prevent damage to the pulser. |
The isolation monitor indicates the isolation of the high-power supply. Refer to Isolation Monitor for more information.