I/O Module Arrangements

For the cRIO-9065, NI InsightCM requires static and dynamic C Series I/O modules installed in a specific arrangement. The following table lists the module types you can install in slots under the different arrangements that NI InsightCM supports.

Table 1. cRIO-9065 I/O Module Arrangements
Slot Number Supported Arrangements
CMS 1 CMS 2 CMS 3 CMS 4 MMS EMSA
1 Static Dynamic Dynamic Dynamic NI 9242 NI 9770
2 Static Dynamic Dynamic Dynamic NI 9239 NI 9770
3 Static Static Dynamic Dynamic NI 9239 NI 9770
4 Static Static Dynamic Dynamic NI 9239 NI 9770
5 Static Static Dynamic Dynamic NI 9239 NI 9770
6 Static Static Dynamic Dynamic NI 9239 NI 9770
7 Static Static Static Dynamic NI 9239 NI 9770
8 Static Static Static Dynamic NI 9239 NI 9770
Note You do not need to fill every slot in the chassis. Fill the slots in order following the arrangements in Table 1.