Complete the following steps before beginning this repair procedure:
  1. Power off your ATE Core Configurations Generation 2 system by flipping the main disconnect branch breaker to off.
  2. If your ATE Core Configurations Generation 2 system utilizes a UPS to provide backup power, press the power button on the UPS to power it down.
  3. Disconnect your ATE Core Configurations Generation 2 system from facility power.
Refer to the following table to see which shipping kits this procedure applies to.
Shipping Kit Part Number Description
789097-01 USB, Ethernet, and DisplayPort Cables

The diagrams in this procedure illustrate the ATE-38U/44U front I/O panel. If you are replacing cables on the rear I/O panel or on the ATE-15U, the same procedure applies.

Equipment

  • 3 mm hex key
  • T8 Torx head screwdriver, (0.76 N · m (6.7 in. · lb)
  1. Remove the ATE Core Configurations Generation 2 left side panel using the 3 mm hex key.
  2. Locate the USB, Ethernet, and display port cables that you are replacing.
  3. Unplug the cables that you are replacing from the equipment they are connected to.
  4. Unscrew the two screws that mount each cable to the I/O panel using the T8 Torx head screwdriver.
  5. Install the new USB, Ethernet and display port cables in the I/O panel using the T8 Torx head screwdriver.
    1. USB port cable
    1. Ethernet port cable
    1. Display port cable
  6. Connect the other end of the new cables to the appropriate end equipment.
  7. Reinstall the ATE Core Configurations Generation 2 left side panel using the 3 mm hex key.

Once installation of the new USB, Ethernet and display port cables are complete, you can reconnect facility power to your ATE Core Configurations Generation 2 system and power on the rack.