USB-6281

Artikelnummer(n):

16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

Übersicht

The USB-6281 offers analog input, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

USB-6281 Einzelheiten

Artikelnummer​n (21) Preis
780054-12
780053-12
780053-11
780053-02
780053-07
780053-06
780053-01
780053-04
780053-03
780054-11
780054-04
780054-02
780054-06
780054-01
780054-03
780054-07
780053-10
780054-09
780053-09
197596-03
780054-10
NI Lead Time
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
27-28 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
Number of Bidirectional Digital Channels
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
Supported Power Input
Taiwan 110VAC
Taiwan 110VAC
Brazil 127/220VAC
Swiss 220VAC
Japan 100VAC
United Kingdom 240VAC
United States 120VAC
Universal Euro 240VAC
Australia 240VAC
Brazil 127/220VAC
Universal Euro 240VAC
Swiss 220VAC
United Kingdom 240VAC
United States 120VAC
Australia 240VAC
Japan 100VAC
China 220VAC
Korea 220VAC
Korea 220VAC
—
China 220VAC
Maximum Number of Single-Ended Analog Input Channels
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Number of Counters/Timers
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Maximum Number of Differential Analog Input Channels
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Analog Input Absolute Accuracy
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
980 μV
Analog Input FIFO Buffer Size
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
2047 samples
Maximum Sample Rate
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
625 kS/s
Analog Input Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Simultaneous Sampling
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Enclosed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Analog Input Resolution
18 bits
18 bits
—
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
18 bits
Bus Connector
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
Front Connection Type
SCSI Type(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
SCSI Type(1)
SCSI Type(1)
SCSI Type(1)
SCSI Type(1)
SCSI Type(1)
SCSI Type(1)
SCSI Type(1)
Screw Terminal(1)
SCSI Type(1)
Screw Terminal(1)
Generic (OEM)(2)
SCSI Type(1)
Number of Analog Output Channels
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Maximum Analog Update Rate
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
2.86 MS/s
Reconfigurable
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Analog Input Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Digital Update Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Operating Temperature Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bus Connection
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
Current Flow Direction
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Logic Levels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Clock Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Input Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Output Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of External Clock Inputs
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Relay Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Signaling Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Supports Peer To Peer Streaming
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Voltage Range
—
—
—
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
—
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-10 V to 10 V
-5 V to 5 V
-2 V to 2 V
-1 V to 1 V
-0.5 V to 0.5 V
-0.2 V to 0.2 V
-0.1 V to 0.1 V
-10 V to 10 V
-5 V to 5 V
-2 V to 2 V
-1 V to 1 V
-0.5 V to 0.5 V
-0.2 V to 0.2 V
-0.1 V to 0.1 V
-10 V to 10 V
-5 V to 5 V
-2 V to 2 V
-1 V to 1 V
-0.5 V to 0.5 V
-0.2 V to 0.2 V
-0.1 V to 0.1 V
-0.1 V to 0.1 V
-0.2 V to 0.2 V
-0.5 V to 0.5 V
-1 V to 1 V
-2 V to 2 V
-5 V to 5 V
-10 V to 10 V
-10 V to 10 V
-5 V to 5 V
-2 V to 2 V
-1 V to 1 V
-0.5 V to 0.5 V
-0.2 V to 0.2 V
-0.1 V to 0.1 V
Filtering
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Current Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Voltage Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Voltage Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Output Current Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Resolution
—
—
18 bits
—
—
—
16 bits
16 bits
—
—
16 bits
—
—
16 bits
—
16 bits
—
—
—
18 bits
—
Analog Input Maximum Absolute Accuracy
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Produktbeschreibung
NI USB-6281 M Series DAQ, Mass Term, NI-DAQMX Driver, Taiwan (110V)
NI USB-6281 M Series DAQ, Screw Term, NI-DAQMX Driver, Taiwan (110V)
NI USB-6281 M Series DAQ, Screw Term, NI-DAQMX Driver, Brazil
USB-6281 M Series DAQ (16 500 kS/s Analog Input, 24 Digital I/O, 2 Analog Outputs) Screw Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Screw Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Screw Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Screw Term
USB-6281 M Series DAQ (16 Analog Input with 500kS/s, 24 Digital I/O, 2 Analog Outputs) Screw Term
USB-6281 M Series DAQ (16 500 kS/s Analog Input, 24 Digital I/O, 2 Analog Outputs) Screw Term
NI USB-6281 M Series DAQ, Mass Term, NI-DAQMX Driver, Brazil
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ (16 500 kS/s Analog Inputs, 24 Digital I/O, 2 Analog Outputs) Mass Term
USB-6281 M Series DAQ Screw Term, DAQmx,SignalExpress LE, Chinese
USB-6281 M Series DAQ Mass Term, DAQmx, SignalExpress LE, Korean
USB-6281 M Series DAQ Screw Term, DAQmx, SignalExpress LE, Korean
USB-6281 M Series OEM
USB-6281 M Series DAQ Mass Term, DAQmx, SignalExpress LE, Chinese

USB-6281 Zubehör und Software

  • Produkt (Artikelnummer)
    Beschreibung
    Empfohlene Anwendungsfälle
    FlexLogger Professional (785748-3501)
    FlexLogger Professional, Subscription License, Download

    Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.

    Key Features

    • Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
    • Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
    • Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
    • Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
    • Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
    • Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
    • CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
    Produktdetails anzeigen
    LabVIEW+ Suite (788509-35)
    NI LabVIEW+ Suite, Subscription License, Download

    Recommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.

    The LabVIEW+ Suite includes the following products:

    • NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
    • NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
    • NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
    • NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
    • NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
    Produktdetails anzeigen

Unterstützung

USB-6281 - NI