USB-6008
Ab $527.00
779051-01
191039-02
779718-01
193132-02
8 AI (12-Bit, 10 kS/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device
Übersicht
The USB-6008 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32-bit counter. The USB-6008 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB-6008 with screw-terminal connectivity. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
Enthaltene Artikel
- Device
- 1 m, USB A 2.0 male-to-USB B male 2.0 USB cable (Included only with part numbers 191039-02 and 779051-01)
- 3.81 mm, 16-pin, cage clam plug (Included only with part number 779051-01)
- Safety, Environmental, and Regulatory documentation
USB-6008 Einzelheiten
Artikelnummern (4) Preis | 779051-01 | 191039-02 | 779718-01 | 193132-02 |
|---|---|---|---|---|
| NI Lead Time | 12-13 weeks | 12-13 weeks | 27-28 weeks | 12-13 weeks |
| Number of Bidirectional Digital Channels | 12 | — | — | 12 |
| Supported Power Input | — | — | — | — |
| Maximum Number of Single-Ended Analog Input Channels | 8 | — | — | 8 |
| Number of Counters/Timers | 1 | — | — | 1 |
| Maximum Number of Differential Analog Input Channels | — | — | — | — |
| Analog Input Absolute Accuracy | — | — | — | — |
| Analog Input FIFO Buffer Size | — | — | — | — |
| Maximum Sample Rate | 10 kS/s | — | — | 10 kS/s |
| Analog Input Isolation | 30 V Ch-Earth Ground Isolation | 30 V Ch-Earth Ground Isolation | 30 V Ch-Earth Ground Isolation | 30 V Ch-Earth Ground Isolation |
| Simultaneous Sampling | — | — | — | — |
| Enclosed | Yes | Yes | Yes | Yes |
| Analog Input Resolution | 12 bits | — | — | 12 bits |
| Bus Connector | USB 2.0 | — | — | USB 2.0 |
| Front Connection Type | Screw Terminal(1) | — | — | Screw Terminal(1) |
| Number of Analog Output Channels | 2 | — | — | 2 |
| Maximum Analog Update Rate | 150 S/s | 150 S/s | 150 S/s | 150 S/s |
| Reconfigurable | No | No | No | No |
| Number of Analog Input Channels | — | — | — | — |
| Maximum Digital Update Rate | — | — | — | — |
| Operating Temperature Range | — | — | — | — |
| Bus Connection | USB 2.0 | — | — | USB 2.0 |
| Current Flow Direction | — | — | — | — |
| Digital I/O Isolation | — | — | — | — |
| Digital I/O Logic Levels | — | — | — | — |
| Maximum Clock Rate | — | — | — | — |
| Number of Digital Input Only Channels | — | — | — | — |
| Number of Digital Output Only Channels | — | — | — | — |
| Number of External Clock Inputs | — | — | — | — |
| Relay Type | — | — | — | — |
| Signaling Type | — | — | — | — |
| Supports Peer To Peer Streaming | — | — | — | — |
| Analog Input Voltage Range | -1 V to 1 V -1.25 V to 1.25 V -2 V to 2 V -2.5 V to 2.5 V -4 V to 4 V -5 V to 5 V -10 V to 10 V -20 V to 20 V | — | — | -1 V to 1 V -1.25 V to 1.25 V -2 V to 2 V -2.5 V to 2.5 V -4 V to 4 V -5 V to 5 V -10 V to 10 V -20 V to 20 V |
| Filtering | — | — | — | — |
| Number of Current Output Channels | — | — | — | — |
| Number of Voltage Output Channels | 2 | 2 | 2 | 2 |
| Analog Output Voltage Range | — | — | — | — |
| Output Current Range | — | — | — | — |
| Analog Output Isolation | — | — | — | — |
| Analog Output Resolution | 12 bits | 12 bits | 12 bits | 12 bits |
| Analog Input Maximum Absolute Accuracy | — | — | — | — |
| Produktbeschreibung | USB-6008 Low-Cost Multifunction I/O and NI-DAQmx | NI USB-6008 12-bit, 10 kS/s multifunction I/O Hardware Only | USB-6008 OEM Board-Only Kit (Quantity 10) | USB-6008 OEM Board Only Kit (No Enclosure) |
USB-6008 Zubehör und Software
- Produkt (Artikelnummer)BeschreibungEmpfohlene AnwendungsfälleFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Ressourcen
Unterstützung
Unterstützung anfordern
Sie können Reparaturen anfordern, Kalibrierungen planen oder technische Unterstützung erhalten. Unter Umständen ist dazu eine Servicevereinbarung erforderlich.
NI Community
Hier können Sie Fragen stellen, sich über Lösungen informieren und an Diskussionen mit anderen Mitgliedern der NI Community teilnehmen.
KnowledgeBase
Suchen Sie nach Antworten auf häufig gestellte Fragen und nach Tipps zur Problembehandlung bei gängigen Fehlern, die von NI-Ingenieuren verfasst wurden.
Online-Schulungen
Greifen Sie auf Hunderte von Lektionen zum Selbststudium und anwendungsorientierte Lernpfade zu, und erleichtern Sie sich den Einstieg mithilfe von Tutorials zur Produkteinrichtung.