NI-9201
Ab $896.00
±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
Übersicht
The NI-9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected signals to the individual channels.
Enthaltene Artikel
- Module
- NI 9980 10-position spring terminal plug (Included only with spring terminal module, part number 783730-01)
- cRIO-9936 10-position screw terminal plug (Included only with screw terminal module, part number 779013-01)
- Regulatory Documentation
NI-9201 Einzelheiten
Artikelnummern (4) Preis | 779013-01 | 189880-51 | 783730-01 | 779372-01 |
|---|---|---|---|---|
| NI Lead Time | 12-13 weeks | 12-13 weeks | 12-13 weeks | 12-13 weeks |
| Maximum Number of Differential Analog Input Channels | 0 | 0 | 0 | 0 |
| Supported Hardware Platform | C Series | C Series | C Series | C Series |
| Conformal Coated | No | No | No | No |
| Analog Input Voltage Range | -10 V to 10 V | -10 V to 10 V | -10 V to 10 V | -10 V to 10 V |
| Enclosed | Yes | Yes | Yes | Yes |
| Analog Input Resolution | 12 bits | 12 bits | 12 bits | 12 bits |
| Maximum Sample Rate | 500 kS/s | 500 kS/s | 500 kS/s | 500 kS/s |
| Analog Input Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation | 60 VDC Ch-Earth Ground Isolation |
| Maximum Number of Single-Ended Analog Input Channels | 8 | 8 | 8 | 8 |
| Front Connection Type | Screw Terminal(1) | Screw Terminal(1) | Spring Terminal(1) | D-SUB(1) |
| Simultaneous Sampling | No | No | No | No |
| Bus Connection | C Series | C Series | C Series | C Series |
| Reconfigurable | — | — | — | — |
| Maximum Analog Update Rate | — | — | — | — |
| Number of Analog Input Channels | — | — | — | — |
| Filtering | Greater than 100 KHz | Greater than 100 KHz | Greater than 100 KHz | Greater than 100 KHz |
| Number of Analog Output Channels | — | — | — | — |
| Number of Current Output Channels | — | — | — | — |
| Number of Voltage Output Channels | — | — | — | — |
| Analog Output Voltage Range | — | — | — | — |
| Output Current Range | — | — | — | — |
| Analog Output Isolation | — | — | — | — |
| Analog Output Resolution | — | — | — | — |
| Number of Bidirectional Digital Channels | — | — | — | — |
| Digital I/O Logic Levels | — | — | — | — |
| Analog Input Absolute Accuracy | — | — | — | — |
| Analog Input Maximum Absolute Accuracy | — | — | — | — |
| Operating Temperature Range | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C |
| Number of Counters/Timers | — | — | — | — |
| Produktbeschreibung | NI 9201 Screw Term, +/-10 V, 12-Bit, 500 kS/s, 8-Ch AI Module | NI 9201 8 ch, 12-Bit, +/-10VDC, 500kS/s, AI, OEM Board Only | NI 9201 Spring Term, +/-10 V, 12-Bit, 500 kS/s, 8-Ch AI Module | NI 9201 DSUB, +/-10 V, 12-Bit, 500 kS/s, 8-Ch AI Module |
NI-9201 Zubehör und Software
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernSH25F-25M (192568-01)SH25F-25M-1 25-Pin Female to Male Shielded I/O Cable, 1 m779372-01
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernNI-9924 (781922-01)NI 9924 Front-mount terminal block for 25-pin D-Sub Modules779372-01
- Produkt (Artikelnummer)BeschreibungEmpfohlene AnwendungsfälleFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Ressourcen
Unterstützung
Unterstützung anfordern
Sie können Reparaturen anfordern, Kalibrierungen planen oder technische Unterstützung erhalten. Unter Umständen ist dazu eine Servicevereinbarung erforderlich.
NI Community
Hier können Sie Fragen stellen, sich über Lösungen informieren und an Diskussionen mit anderen Mitgliedern der NI Community teilnehmen.
KnowledgeBase
Suchen Sie nach Antworten auf häufig gestellte Fragen und nach Tipps zur Problembehandlung bei gängigen Fehlern, die von NI-Ingenieuren verfasst wurden.
Online-Schulungen
Greifen Sie auf Hunderte von Lektionen zum Selbststudium und anwendungsorientierte Lernpfade zu, und erleichtern Sie sich den Einstieg mithilfe von Tutorials zur Produkteinrichtung.