FD-11637
Ab $3,947.00
8-Channel Strain/Bridge Input Device for FieldDAQ
Übersicht
The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 provides precise, synchronized timing over the network using Time Sensitive Networking (TSN), ideal for highly distributed measurements over long distances. The device features an integrated network switch for simple daisy-chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.
Enthaltene Artikel
- Device
- Safety, Environmental, and Regulatory documentation
FD-11637 Einzelheiten
Artikelnummern (1) Preis | 785641-01 |
|---|---|
| NI Lead Time | 16-17 weeks |
| Bridge Configurations | Quarter Bridge Half Bridge Full Bridge |
| Maximum Number of Differential Analog Input Channels | 8 |
| Conformal Coated | No |
| Analog Input Voltage Range | -38 mV/V to 38 mV/V |
| Enclosed | Yes |
| Maximum Sample Rate | 100 kS/s/ch |
| Simultaneous Sampling | Yes |
| Front Connection Type | M12 X-coded(2) M12 L-coded(2) M12 A-coded(8) |
| Supported Hardware Platform | Computer-Based Device |
| Number of Analog Input Channels | 8 |
| Operating Temperature Range | -40 °C to 85 °C |
| Bus Connection | Ethernet |
| Analog Input Isolation | 60 VDC Ch-Ch Isolation |
| Bridge Resistance | 120 Ohm 350 Ohm |
| Supported Sensor Type | Bridge Strain Gauge |
| Produktbeschreibung | FD-11637, IP67, 8 ch 1/4, 1/2, full bridge input, 100 kS/s/ch, 24-bit, Strain/Bridge Input Device |
FD-11637 Zubehör und Software
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernSHM128M-RJ45 (785944-01)IP67 Gigabit Ethernet, Shielded X-Code M12 Male to RJ45 (Straight), 1M for FieldDAQ785641-01SHM128M-SHM128M-RA (785945-0R3)IP67 Gigabit Ethernet, Shielded X-Code M12 Male to Shielded M12 Male (Right Angle) 0.3M for FieldDAQ785641-01SHM128M-SHM128M (785946-01)IP67 Gigabit Ethernet, Shielded X-Code M12 Male to Shielded M12 Male (Straight), 1M for FieldDAQ785641-01SHM128M-RJ45-RA (786171-01)IP67 Gigabit Ethernet, Shielded X-Code M12 Male to RJ45 (Right Angle), 1M for FieldDAQ785641-01M125F-M125M (786173-01)IP67, Power, L-Code M12 Female to L-Code M12 Male (Straight), 1M for FieldDAQ785641-01
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernIP67 Power Supply (147464-01)IP67 Power Supply, 24 VDC, 5 A, 100-240 VAC Input785641-01
- Produkt (Artikelnummer)BeschreibungEmpfohlene AnwendungsfälleFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Ressourcen
Unterstützung
Unterstützung anfordern
Sie können Reparaturen anfordern, Kalibrierungen planen oder technische Unterstützung erhalten. Unter Umständen ist dazu eine Servicevereinbarung erforderlich.
NI Community
Hier können Sie Fragen stellen, sich über Lösungen informieren und an Diskussionen mit anderen Mitgliedern der NI Community teilnehmen.
KnowledgeBase
Suchen Sie nach Antworten auf häufig gestellte Fragen und nach Tipps zur Problembehandlung bei gängigen Fehlern, die von NI-Ingenieuren verfasst wurden.
Online-Schulungen
Greifen Sie auf Hunderte von Lektionen zum Selbststudium und anwendungsorientierte Lernpfade zu, und erleichtern Sie sich den Einstieg mithilfe von Tutorials zur Produkteinrichtung.