NI-9472
Ab $213.00
24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module
Übersicht
The NI-9472 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 30 V, features transient overvoltage protection between the output channels and the backplane, and has an LED that indicates the status.
Enthaltene Artikel
- Module
- 10-position spring terminal plug (NI-9980) (included only with spring terminal module, part number 783907-01)
- 10-position screw terminal plug (NI-9936) (included only with screw terminal module, part number 779004-01)
- Safety, Environmental, & Regulatory documentation
NI-9472 Einzelheiten
Artikelnummern (5) Preis | 189200-51 | 779004-02 | 783907-01 | 779004-01 | 779137-01 |
|---|---|---|---|---|---|
| NI Lead Time | 12-13 weeks | 8-9 weeks | 8-9 weeks | 8-9 weeks | 8-9 weeks |
| Supported Hardware Platform | C Series | C Series | C Series | C Series | C Series |
| Number of Bidirectional Digital Channels | 0 | 0 | 0 | 0 | 0 |
| Conformal Coated | No | Yes | No | No | No |
| Current Flow Direction | Sourcing Output | Sourcing Output | Sourcing Output | Sourcing Output | Sourcing Output |
| Enclosed | Yes | Yes | Yes | Yes | Yes |
| Digital I/O Logic Levels | 12 V 24 V | 12 V 24 V | 12 V 24 V | 12 V 24 V | 12 V 24 V |
| Digital I/O Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation | 250 Vrms Ch-Earth Ground Isolation |
| Front Connection Type | Screw Terminal(1) | Screw Terminal(1) | Spring Terminal(1) | Screw Terminal(1) | D-SUB(1) |
| Number of Digital Input Only Channels | 0 | 0 | 0 | 0 | 0 |
| Number of Digital Output Only Channels | 8 | 8 | 8 | 8 | 8 |
| Maximum Digital Update Rate | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs |
| Reconfigurable | — | — | — | — | — |
| Maximum Sample Rate | — | — | — | — | — |
| Number of Analog Input Channels | — | — | — | — | — |
| Maximum Analog Update Rate | — | — | — | — | — |
| Number of Analog Output Channels | — | — | — | — | — |
| Operating Temperature Range | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C |
| Bus Connection | C Series | C Series | C Series | C Series | C Series |
| Maximum Clock Rate | 10 kHz | — | 10 kHz | 10 kHz | 10 kHz |
| Number of Counters/Timers | — | — | — | — | — |
| Number of External Clock Inputs | — | — | — | — | — |
| Relay Type | — | — | — | — | — |
| Signaling Type | Single-Ended | Single-Ended | Single-Ended | Single-Ended | Single-Ended |
| Supports Peer To Peer Streaming | — | — | — | — | — |
| Produktbeschreibung | NI 9472 8 ch 24 V, 100 us, Sourcing DO, OEM Board Only | NI 9472 Conformal Coated, 8-Ch, 24 V, 100 us, Sourcing DO Module | NI 9472 Spring Term, 24 V, 100 µs, 8-Ch, Sourcing DO Module | NI 9472 8-Ch 24 V, 100 us, Sourcing DO Module | NI 9472 with DSub 8-Ch 24 V, 100 us, Sourcing DO Module |
NI-9472 Zubehör und Software
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernSH25F-25M (192568-01)SH25F-25M-1 25-Pin Female to Male Shielded I/O Cable, 1 m779137-01
- Modell (Artikelnummer)BeschreibungBildKompatible ArtikelnummernNI-9924 (781922-01)NI 9924 Front-mount terminal block for 25-pin D-Sub Modules779137-01
- Produkt (Artikelnummer)BeschreibungEmpfohlene AnwendungsfälleFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Ressourcen
Unterstützung
Unterstützung anfordern
Sie können Reparaturen anfordern, Kalibrierungen planen oder technische Unterstützung erhalten. Unter Umständen ist dazu eine Servicevereinbarung erforderlich.
NI Community
Hier können Sie Fragen stellen, sich über Lösungen informieren und an Diskussionen mit anderen Mitgliedern der NI Community teilnehmen.
KnowledgeBase
Suchen Sie nach Antworten auf häufig gestellte Fragen und nach Tipps zur Problembehandlung bei gängigen Fehlern, die von NI-Ingenieuren verfasst wurden.
Online-Schulungen
Greifen Sie auf Hunderte von Lektionen zum Selbststudium und anwendungsorientierte Lernpfade zu, und erleichtern Sie sich den Einstieg mithilfe von Tutorials zur Produkteinrichtung.