NI InsightCM 3.4 Known Issues

Overview

This document contains the InsightCM 3.4 known issues that were discovered before and since the release of InsightCM 3.4. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.

Known Issues by Category

The following items are known issues in InsightCM 3.4 sorted by Category.

InsightCM Monitoring Devices
 727573InsightCM does not warn user that calculated MCSA features cannot be used for gating and delta EU
InsightCM Web Application
 680791Users are unable to create Baselines Data Events for Thermal Camera ROI and Delta Features
 682841Device Dashboard does not show alarms on integrated features
 686624Server-only Features are selectable as Delta EU Operating State Triggers
 731674Order Waveform and Spectrum viewers don't display data if there are only two tachometer pulses
 735127Default OPC security policies are invalid

 

IDKnown Issue
 InsightCM Monitoring Devices
 727573

Return
InsightCM does not warn user that calculated MCSA features cannot be used for gating and delta EU
Using calculated features from an MCSA asset for gating conditions or delta EU triggers will cause an invalid configuration. InsightCM currently does not notify the user of this when creating the asset configuration.

Workaround: N/A

Reported Version: 3.3  Resolved Version: -  Added: 04/08/2019
 InsightCM Web Application
 680791

Return
Users are unable to create Baselines Data Events for Thermal Camera ROI and Delta Features
.

Workaround: N/A

Reported Version: 3.2  Resolved Version: -  Added: 04/08/2019
 682841

Return
Device Dashboard does not show alarms on integrated features


Workaround: Use the Alarm Tab on the primary Dashboard page.

Reported Version: 3.2  Resolved Version: -  Added: 04/08/2019
 686624

Return
Server-only Features are selectable as Delta EU Operating State Triggers
Users can specify these server calculated only features as a source for delta EU triggers. Features that are calculated on the server only (such as the envelope bands) cannot trigger a delta EU data collection.

Workaround: Do not use server calculated only features as Operating State triggers.

Reported Version: 3.2  Resolved Version: 3.5  Added: 04/08/2019
 731674

Return
Order Waveform and Spectrum viewers don't display data if there are only two tachometer pulses
When doing slow roll compensation in order waveform or order spectrum viewers, an error is returned if there is only one revolution in the slow roll data.

Workaround: N/A

Reported Version: 3.2  Resolved Version: -  Added: 04/08/2019
 735127

Return
OPC Historian does not start after upgrade or fresh install
If you have not selected an OPC security policy besides "None", the OPC Historian will be unable to start.

Workaround: Select an OPC security policy on the InsightCM Options page. If you do not want any additional security policies selected, you can then deselect all policies besides "None". The OPC Historian should start after restarting the server.

Reported Version: 3.4  Resolved Version: 3.5  Added: 05/02/2019

Document last updated on 05/02/2019

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).