SystemLink 2021 R1 Known Issues

Überblick

This document contains the SystemLink known issues that were discovered before and since the release of SystemLink 2021 R1. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

Bug Number

Legacy ID

Description

Details

211182

Using the browser navigation buttons does not correctly change a query

On pages with a query panel (Assets, Calibrated Assets, Reports, etc.), the browser back button does not work as expected. When a user presses the back button, the URL in the browser changes, but the filters do not.

Workaround:

Remove the filter using the X button next to the property selection field instead.

Reported Version:

SystemLink 19.5

Resolved Version:

N/A

Added:

Feb 27, 2020

1077209

Packages disappear from grid when viewed in Safari full screen mode

Package Repository application fails to display packages in the feed's detail view when done from Safari in full screen mode.


Workaround:

Use a different browser such as Chrome or take Safari out of full screen mode.

Reported Version:

SystemLink 2020 R3

Resolved Version:

N/A

Added:

Dec 10, 2020

1038431, 1379439

Stored test results can be sent to the incorrect server when client registration is changed while forwarding is in progress

If the store & forward plugin is already loaded and forwarding steps, it continues to forward to the original server connection even if the server is changed.  It will not switch servers while there are current transactions on disk and still successfully forwarding them.  Since simply switching the master does not invalidate the old API key, then if the server is still accessible, the forwarding plugin does not know that it should switch to the new master.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

SystemLink 2020 R2

Resolved Version:

N/A

Added:

Dec 11, 2020

1350133

Windows login account cannot be used as TDM User Account

Logging into the Windows SystemLink servers with different user accounts can create issues with TDM services like DataFinder in case when one of these login accounts is also being used as SystemLink TDM User Account.

Workaround:

Assign a specific user/account to SystemLink TDM services.

Reported Version:

SystemLink 2020 R4

Resolved Version:

N/A

Added:

Apr 27, 2021

1411798

LabVIEW RT targets show "partially connected" status in Systems Grid due to failing http requests from the client when using self-signed certificates

The NI Web Server Configuration Utility is adding ipv6 addresses to the SAN of the certificate. This is causing http requests coming from the client to fail because of a known bug in urllib3: Connection fails via https when certificate contains IPv6 address in SAN · Issue #1269 · urllib3/urllib3 (github.com)

This breaks the RT target's ability to connect and publish data when using self-signed certificates because NI LinuxRT uses a version of urllib3 that does not contain the above fix.

Workaround:

To resolve the issue, navigate to the NI Web Server Configuration Utility and complete the following steps:
  1. Navigate to the HTTPS tab
  2. In the HTTPS settings section, expand the "Generate a new certificate" section
  3. Find the entry containing "::1" and hit the "Remove" button
  4. Click the "Generate and install" button and follow the remaining steps in the utility to generate a new certificate

Reported Version:

SystemLink 2021 R1

Resolved Version:

N/A

Added:

Apr 12, 2021

1420676

Custom NoSqlDatabase connection string does not allow lower case URL encoding

Setting a custom connection string in the NoSqlDatabase configuration requires any special characters to be URL encoded.  Using lower case characters within the URL encoding will cause the string to be incorrectly regarded as invalid.

Workaround:

Use only upper case characters within the URL encoding.  For example, %3d will be considered invalid, but %3D will work correctly.

Reported Version:

SystemLink 2021 R1

Resolved Version:

N/A

Added:

Apr 27, 2021

1422638, 1433322

[Analysis Automation] Manual approval of Analysis Procedures required after upgrade

When upgrading from a SystemLink version prior to 2021, existing procedures are not approved automatically.
However, existing and active tasks are still working, but cannot be edited and new tasks cannot be created, until the procedure has been approved.

Workaround:

Manually approve the according Analysis Procedures.

Reported Version:

SystemLink 2020 R4

Resolved Version:

SystemLink 2021 R1.1

Added:

Apr 27, 2021

1516963

Canceling a report or notebook execution causes the worker to stop functioning

Canceling a notebook execution from the Test Insights Report view causes the worker process to throw an exception, and it can no longer be used. There are 4 notebook execution workers by default, so if this happens multiple times, you will no longer be able to execute any notebooks or reports. In addition, reports in dashboards will no longer be updated.

Workaround:

Rebooting the server will restart the notebook execution workers and allow everything to work temporarily.

Reported Version:

SystemLink 2021 R1

Resolved Version:

SystemLink 2021 R2

Added:

Jul 9, 2021

1706828

DataFinder stopped because SL TDM Database Service crashed

Workaround:

There is currently no known workaround for this issue.

Reported Version:

SystemLink 2021 R1

Resolved Version:

SystemLink 2021 R1.2

Added:

Nov 24, 2021

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.