Analyzing and Saving a Signal (Full and Professional)

Publish Date: Feb 18, 2008 | 1 Ratings | 5.00 out of 5 |  PDF

Overview

LabVIEW includes a set of Express VIs that help you analyze signals. This chapter teaches you how to use LabVIEW to perform a basic analysis of a signal and how to save the analyzed data to a file.

Note: The exercises in this chapter use Express VIs that are available only in the LabVIEW Full and Professional Development Systems.

You can complete the exercises in this chapter in approximately 40 minutes.

Table of Contents

  1. Building an Analysis VI
  2. Summary

1. Building an Analysis VI

In the following exercises, you will build a VI that generates a signal, filters the signal, indicates if the signal exceeds a certain limit, and records the data. After you complete the exercises, the front panel of the VI will look similar to the front panel in Figure 1.

Figure 1. Front Panel of the Save Data VI

Modifying a VI Created from a Template

Complete the following steps to create a VI that generates, analyzes, and displays a signal.

1. In the Getting Started window, click New to display the New dialog box. 

2. From the Create New list, select VI»From Template»Tutorial (Getting Started)»Generate, Analyze, and Display. This template VI simulates a signal and analyzes it for its root mean square (RMS) value. 

3. Click the OK button or double-click the name of the template to create a VI from the template. 

4. If the Context Help window is not visible, press the <Ctrl-H> keys to display the window. (Mac OS) Press the <Command-Shift-H> keys. 

5. Display the block diagram by pressing the <Ctrl-E> keys. 

6. Move the cursor over the Amplitude and Level Measurements Express VI, shown at left. 

The Context Help window displays information about the behavior of the Express VI. Keep the Context Help window open. It will provide useful information as you complete the rest of this exercise. 

7. On the front panel, remove the RMS indicator along with any broken wires on the block diagram that result from removing the indicator. To remove all broken wires from the block diagram, you can press the <Ctrl-B> keys. You will not use the RMS functionality of the Amplitude and Level Measurements Express VI for this exercise. However, you can use the Generate, Analyze, and Display template VI with the RMS functionality in a future project to reduce development time. 

8. On the front panel, right-click the waveform graph indicator and select Properties from the shortcut menu. The Graph Properties dialog box appears. 

9. On the Appearance tab, place a checkmark in the Visible checkbox in the Label section and enter Unfiltered Signal in the text box. 

10. Click the OK button to save the configuration and close the Graph Properties dialog box. 

11. Run the VI. 

The signal appears in the graph. 

12. Click the STOP button to stop the VI.

Adding a Signal

The Simulate Signal Express VI simulates a sine wave by default. You can customize the simulated signal by changing the options in the Configure Simulate Signal dialog box. Complete the following steps to create an additional simulated signal that adds uniform white noise to the sine wave. 

1. On the block diagram, use the Positioning tool to select the Simulate Signal Express VI. Hold down the <Ctrl> key and drag to create an additional Simulate Signal Express VI on the block diagram. (Mac OS) Hold down the key and drag. (Linux) Hold down the middle mouse button and drag. 

2. Release the mouse button to place the copied Simulate Signal Express VI below the original Simulate Signal Express VI. LabVIEW updates the name of the copied Simulate Signal Express VI to Simulate Signal2. 

3. Double-click the Simulate Signal2 Express VI to display the Configure Simulate Signal dialog box. 

4. Select Sine from the Signal type pull-down menu. 

5. Enter 60 in the Frequency (Hz) text box. 

6. Enter .1 in the Amplitude text box. 

7. Place a checkmark in the Add noise checkbox to add noise to the sine signal. 

8. Select Uniform White Noise from the Noise type pull-down menu.

9. Enter 0.1 in the Noise amplitude text box. 

10. Enter -1 in the Seed number text box. 

11. In the Timing section, select the Run as fast as possible option. 

12. In the Signal Name section, remove the checkmark from the Use signal type name checkbox. 

13. Enter 60 Hz and Noise in the Signal name text box. 

When you change the signal name in the Configure Simulate Signal dialog box, LabVIEW changes the name of the signal output on the block diagram. Changing the signal name makes it easier for you to identify the signal type when you view the Express VI on the block diagram. 

The Result Preview section displays a random signal. The Configure Simulate Signal dialog box should appear similar to Figure 2.

Figure 2. Configure Simulate Signal Dialog Box

14. Click the OK button to save the current configuration and close the Configure Simulate Signal dialog box.

Adding Two Signals

To add two signals together to create one signal, you can use the Formula Express VI. Rather than merging two signals on one graph, the Formula Express VI adds both signals together to create a single signal on the graph. You can use this Express VI to add noise to a signal. Complete the following steps to add the 60 Hz and Noise signal to the Sine signal. 

1. On the block diagram, triple-click the wire that connects the Sine output of the Simulate Signal Express VI to the Signals input of the Amplitude and Level Measurements Express VI and to the Unfiltered Signal indicator and remove the wire. 

2. Click the Search button on the Functions palette to search for the Formula Express VI. and place it on the block diagram between the Simulate Signal Express VIs and the Amplitude and Level Measurements Express VI. 

3. The Configure Formula dialog box appears in the Label column. Change the label for X1 to Sine and the label for X2 to 60 Hz and Noise

4. Click the Input and + buttons to add Sine and 60 Hz and Noise together in the String text box. 

5. Click the OK button to save the current configuration and close the Configure Formula dialog box. 

6. Use the Wiring tool to wire the Sine output of the Simulate Signal Express VI to the Sine input of the Formula Express VI. 

7. Wire the 60 Hz and Noise output of the Simulate Signal2 Express VI to the 60 Hz and Noise input of the Formula Express VI. 

8. Wire the Result output of the Formula Express VI to the Unfiltered Signal indicator and to the Signals input of the Amplitude and Level Measurements Express VI. 

9. Display the front panel by pressing the <Ctrl-E> keys. 

10. Run the VI. 

The signal with added noise appears in the graph. 

11. Click the STOP button to stop the VI. 

12. Select File»Save As and save the VI as Analysis.vi in an easily accessible location.

Filtering a Signal

You can use the Filter Express VI to process signals through filters and windows. Complete the following steps to configure the Filter Express VI to filter the signal using an infinite impulse response (IIR) filter. 

1. Remove the wire that connects the Result output of the Formula Express VI to the Signals input of the Amplitude and Level Measurements Express VI. 

2. Remove all broken wires that result from removing the wire. 

3. Search for the Filter Express VI and place it on the block diagram between the Simulate Signal2 Express VI and the Amplitude and Level Measurements Express VI. The Configure Filter dialog box appears. 

4. In the Filter Specifications section, change the Cutoff Frequency (Hz) to 25

5. Click the OK button to save the configuration and close the Configure Filter dialog box. 

6. Display the front panel. 

7. Click the Unfiltered Signal waveform graph indicator on the front panel and press the <Ctrl> key while you drag to create an additional waveform graph indicator. 

8. Place the additional waveform graph indicator below the Unfiltered Signal waveform graph. 

9. Triple-click the Unfiltered Signal 2 label above the new waveform graph indictor and enter Filtered Signal to change the label of the indicator. You also can change the label on the Appearance page of the Graph Properties dialog box. 

10. On the block diagram, wire the Result output of the Formula Express VI to the Signal input of the Filter Express VI. 

11. Wire the Filtered Signal output of the Filter Express VI to the Signals input of the Amplitude and Level Measurements Express VI and to the input of the Filtered Signal waveform graph indicator. 

12. Select File»Save. The block diagram of the Analysis VI should appear similar to Figure 3.

Figure 3. Block Diagram of the Analysis VI

Modifying the Appearance of Graphs

You can use the Format and Precision page of the Graph Properties dialog box to specify how the scales of the x-axis and y-axis appear on the graph. Complete the following steps to change the format of the x-axis and y-axis of the Unfiltered Signal and Filtered Signal graphs. 

1. On the front panel, right-click the Unfiltered Signal graph indicator and select Properties from the shortcut menu. The Graph Properties dialog box appears. 

2. On the Format and Precision page, select Time (X-Axis) from the top pull-down menu. 

3. In the Type list, select Automatic formatting

4. In the Digits field, enter 6 and select Significant digits from the Precision Type pull-down menu. 

5. Place a checkmark in the Hide trailing zeros checkbox. 

6. Select Amplitude (Y-Axis) from the top pull-down menu and repeat steps 3–5 so the y-axis configuration matches the x-axis configuration. 

7. On the Scales page, select Amplitude (Y-Axis)

8. Remove the checkmark from the Autoscale checkbox. 

9. Enter -2.5 in the Minimum text box and 2.5 in the Maximum text box. 

10. Click the OK button to save the configuration and close the Graph Properties dialog box. 

11. Repeat steps 1–10 to configure the Filtered Signal graph indicator. The x-axis and the y-axis on the Unfiltered Signal and Filtered Signal graph indicators change to reflect the new configuration.

Analyzing the Amplitude of a Signal

You can use the Amplitude and Level Measurements Express VI to analyze the voltage characteristics of a signal. Complete the following steps to reconfigure the Express VI to measure the peak-to-peak amplitude values of the signal. 

1. On the block diagram, double-click the Amplitude and Level Measurements Express VI to display the Configure Amplitude and Level Measurements dialog box. 

2. In the Amplitude Measurements section, remove the checkmark from the RMS checkbox.

3. Place a checkmark in the Peak to peak checkbox. Peak to peak appears in the Results section with the corresponding value of the measurement. 

4. Click the OK button to save the current configuration and close the Configure Amplitude and Level Measurements dialog box. 

The RMS output of the Amplitude and Level Measurements Express VI changes to reflect the new Peak to Peak output.

Controlling the Speed of Execution

To plot the points on the waveform graphs more slowly, you can add a time delay to the block diagram. 

Complete the following steps to control the speed at which the VI runs. 

1. Search for the Time Delay Express VI. 

2. Place the Time Delay Express VI in the lower left-hand corner of the While Loop. The Configure Time Delay dialog box appears. 

3. Enter .1 in the Time delay (seconds) text box and click the OK button. 

4. Run the VI. The loop iterates once every tenth of a second.

Adding a Warning Light

If you want a visual cue to indicate when a value exceeds a specified limit, you can use a warning light. 

Complete the following steps to add a warning light to the VI. 

1. On the front panel, display the Controls palette by right-clicking any blank space on the front panel. 

2. On the Express palette, select the LEDs palette, shown in Figure 4.

Figure 4. LEDs Palette

3. Select the round LED indicator and place it on the front panel to the left of the waveform graphs. 

4. Double-click the Boolean label above the LED and enter Warning to change the label of the LED. You will use this LED in a later exercise to indicate when a value has exceeded its limit. 

5. Select File»Save As to display the Save As dialog box. 

6. Read the various dialog box options. Select the Copy and Substitute copy for original radio buttons to create a copy of the original VI and immediately edit the copy. 

7. Click the Continue button and save the VI as Warning Light.vi in an easily accessible location.

Setting a Warning Level Limit

To specify the value at which you want the LED to light, use the Comparison Express VI. Complete the following steps to compare the peak-to-peak value to a limit you set. 

8. Search for the Comparison Express VI and place it to the right of the Amplitude and Level Measurements Express VI. The Configure Comparison dialog box appears. 

9. In the Compare Condition section, select the > Greater option. 

10. In the Comparison Inputs section, select Value and enter 2 in the Value text box to assign a constant value at which you want the LED to light. 

11. Click the OK button to save the current configuration and close the Configure Comparison dialog box. 

The name of the Comparison Express VI changes to reflect the operation of the Express VI, shown at left. Greater indicates that the Express VI does a greater than comparison. 

12. Wire the Peak to Peak output of the Amplitude and Level Measurements Express VI to the Operand 1 input of the Greater Express VI. 

13. Move the cursor over the wire that connects the Peak to Peak output to the Operand 1 input. 

14. When the Positioning tool appears, right-click the wire that connects the Peak to Peak output to the Operand 1 input and select Create»Numeric Indicator from the shortcut menu. 

A Peak to Peak terminal appears on the block diagram. If the Peak to Peak terminal appears to be on top of the wires between the Express VIs, move the Express VIs and Peak to Peak terminal around to create more space. For example, move the Peak to Peak terminal into blank space above the Express VIs.

Warning the User

After you specify the values at which you want the LED to light, you must wire the LED to the Greater Express VI. 

Complete the following steps to provide a visual cue when the peak-to-peak value of the signal exceeds a specified limit. 

1. On the block diagram, move the Warning terminal to the right of the Greater Express VI. Make sure the Warning terminal is inside the While Loop, as shown in Figure 5.

Figure 5. Block Diagram of the Warning Light VI

2. Wire the Result output of the Greater Express VI to the Warning terminal. 

The block diagram should appear similar to Figure 5. 

3. Display the front panel. 

A numeric indicator labeled Peak to Peak appears on the front panel. This indicator displays the peak-to-peak value of the signal. 

4. Run the VI. When the peak-to-peak value exceeds 2.0, the Warning indicator lights. 

5. Click the STOP button to stop the VI. 

6. Save the VI.

Configuring a VI to Save Data to a File

To store information about the data a VI generates, use the Write To Measurement File Express VI. Complete the following steps to build a VI that saves peak-to-peak values and other information to a LabVIEW data file. 

1. Search for the Write To Measurement File Express VI and place it on the block diagram below and to the right of the Amplitude and Level Measurements Express VI. 

The Configure Write To Measurement File dialog box appears.

The File Name text box displays the full path to the output file, test.lvm. A .lvm file is a tab-delimited text measurement file you can open with a spreadsheet application or a text-editing application. LabVIEW saves data with up to six digits of precision in a .lvm file. LabVIEW saves the .lvm file in the default LabVIEW Data directory. LabVIEW installs the LabVIEW Data directory in the default file directory of the operating system. 

When you want to view the data, use the file path displayed in the File Name text box to access the test.lvm file. 

2. In the If a file already exists section of the Configure Write To Measurement File dialog box, select the Append to file option to write all the data to the test.lvm file without erasing any existing data in the file. 

3. In the Segment Headers section, select the One header only option to create only one header in the file to which LabVIEW writes the data. 

4. Enter the following text in the File Description text box: Sample of peak to peak values. LabVIEW appends the text you enter in this text box to the header of the file. 

5. Click the OK button to save the current configuration and close the Configure Write To Measurement File dialog box.

Saving Data to a File

When you run the VI, LabVIEW saves the data to the test.lvm file.

Complete the following steps to generate the test.lvm file. 

1. On the block diagram, wire the Peak to Peak output of the Amplitude and Level Measurements Express VI to the Signals input of the Write To Measurement File Express VI. 

2. Select File»Save As and save the VI as Save Data.vi in an easily accessible location. 

3. Display the front panel and run the VI. 

4. Click the STOP button on the front panel. 

5. To view the data you saved, open the test.lvm file in the LabVIEW Data directory with a spreadsheet or text-editing application. 

The file has a header which contains information about the Express VI. 

6. Close the file after you finish looking at it and return to the Save Data VI.

Adding a Button That Stores Data When Clicked

If you want to store only certain data points, you can configure the Write To Measurement File Express VI to save peak-to-peak values only when a user clicks a button. Complete the following steps to add a button to the VI and configure how the button responds when a user clicks it. 

1. Search the Controls palette for the rocker button. Select one of the rocker buttons and place it to the right of the waveform graphs. 

2. Right-click the rocker button and select Properties from the shortcut menu to display the Boolean Properties dialog box. 

3. Change the label of the button to Write to File

4. On the Operation page of the Boolean Properties dialog box, select Latch when pressed from the Button behavior list. Use the Operation page to specify how a button behaves when a user clicks it. To see how the button reacts to a click, click the button in the Preview Selected Behavior section. 

5. Click the OK button to save the current configuration and close the Boolean Properties dialog box. 

6. Save the VI.

Saving Data When Prompted by a User

Complete the following steps to build a VI that logs data to a file when the user clicks a button on the front panel. 

1. On the block diagram, double-click the Write To Measurement File Express VI to display the Configure Write To Measurement File dialog box. 

2. Change the filename test.lvm in the File Name text box to Selected Samples.lvm to save the data to a different file. 

3. Click the OK button to save the current configuration and close the Configure Write To Measurement File dialog box. 

4. Right-click the Signals input of the Write To Measurement File Express VI and select Insert Input/Output from the shortcut menu to insert the Comment input. 

5. Right-click the Comment input of the Write To Measurement File Express VI and select Select Input/Output»Enable from the shortcut menu to replace the Comment input with the Enable input. 

The inputs and outputs of an Express VI appear in a predetermined order when you add new inputs and outputs. To select a specific input, you might need to add an input first, then change the input to the specific one you want to use by right-clicking the input and selecting Select Input/Output from the shortcut menu. 

6. Move the Write to File terminal to the left of the Write To Measurement File Express VI. 

7. Wire the Write to File terminal to the Enable input of the Write To Measurement File Express VI. 

The block diagram should appear similar to Figure 6.

Figure 6. Block Diagram of the Save Data VI

Viewing Saved Data

Complete the following steps to view the data that you save to the Selected Samples.lvm file. 

1. Display the front panel and run the VI. Click the Write to File button several times. 

2. Click the STOP button on the front panel. 

3. Open the Selected Samples.lvm file with a spreadsheet or text-editing application. 

The Selected Samples.lvm file differs from the test.lvm file. test.lvm recorded all the data generated by the Save Data VI, whereas Selected Samples.lvm recorded data only when you clicked the Write to File button. 

4. Close the file after you finish looking at it. 

5. Save and close the VI.

Back to Top

2. Summary

The following topics are a summary of the main concepts you learned in this chapter.

Controls and Indicators

You can configure the controls and indicators on the front panel to perform tasks depending on what you want a VI to do. In this chapter, you learned to use controls and indicators in the following ways: 

• You can build VIs that perform a task when certain conditions occur, such as displaying a warning light when a value exceeds a certain limit. 

• You can build VIs that let users control when an Express VI executes by using buttons and the Enable input. You can configure the buttons to operate in one of six ways using the Operation page of the Boolean Properties dialog box.

Filtering Data

The Filter Express VI processes signals through filters and windows. You can use the Filter Express VI to remove noise from a signal.

Saving Data

The Write To Measurement File Express VI saves data that a VI generates and analyzes to a .lvm, .tdm, or .tdms measurement file. The text-based measurement file (.lvm) is a tab-delimited text file you can open with a spreadsheet application or a text-editing application. LabVIEW saves data with up to six digits of precision in a .lvm file. In addition to the data an Express VI generates, the .lvm file includes headers that contain information about the data, such as the date and time LabVIEW generated the data. The binary measurement file (.tdm) is a binary file that contains waveform data. Binary .tdm files provide higher accuracy for floating-point numbers, have a smaller disk footprint, and perform faster than text-based measurement files (.lvm). The TDM Streaming file (.tdms) is a binary file that provides faster writing performance than the .tdm file format and allows a simpler interface for defining properties. 

LabVIEW installs the LabVIEW Data directory in the default file directory of the operating system to help you organize and locate the data files LabVIEW generates. Refer to the LabVIEW Help for more information about writing data to and reading data from .lvm and .tdm files.

Back to Top