Automated Calibration Software

发布日期: Mar 25, 2014 | 0 Ratings | 0.00 out of 5 |  PDF

概览

NI Calibration Executive utilizes external calibration standards to verify and adjust the performance of NI measurement hardware. Calibration Executive provides an intuitive user interface to guide you through the configuration and calibration procedures, and fully automates the process for supported instruments. In addition, Calibration Executive provides reporting capabilities for documenting the calibration results.

目录

  1. NI Calibration Executive 3.5
  2. User Interface
  3. System Requirements
  4. Calibration Executive Updates
  5. Additional Resources

1. NI Calibration Executive 3.5

A summary of supported products and system requirements is listed below:

Distributed I/O

FieldPoint Modules

Verification & Adjustment Verification Only
FP-AI-100/102/110/111/112
FP-AO-200/210  
FP-AIO-600/610  
FP-RTD-122/124  
FP-TC-120  

Compact FieldPoint Modules

cFP-AI-100/102/110/111/112/118
cFP-AO-200/210  
cFP-AIO-600/610  
cFP-RTD-122/124  
cFP-TC-120  

C Series Devices

Verification & Adjustment Verification Only
NI 9205 NI 9201
NI 9206 NI 9203
  NI 9211
  NI 9213
  NI 9215
  NI 9217
  NI 9221
  NI 9225
  NI 9229
  NI 9234
  NI 9235
  NI 9236
  NI 9237
  NI 9239
  NI 9263
  NI 9264
  NI 9265

Data Acquisition (DAQ) Devices

Analog Output

Verification & Adjustment Verification Only
NI 6703/6704
NI 6711/6713/6715  
NI 6722/6723  
NI 6731/6733  

B Series

Verification & Adjustment Verification Only
NI 6010
NI 6013  
NI 6014  

CompactDAQ

Verification & Adjustment Verification Only
NI cDAQ-9171
  NI cDAQ-9172
  NI cDAQ-9174
  NI cDAQ-9178
  NI cDAQ-9181
  NI cDAQ-9188
  NI cDAQ-9191

E Series

Verification & Adjustment Verification Only
NI AT-AI-16XE-10
NI AT-MIO-16DE-10  
NI AT-MIO-16E-1  
NI AT-MIO-16E-10  
NI AT-MIO-16E-2  
NI AT-MIO-16XE-10  
NI AT-MIO-16XE-50  
NI AT-MIO-64E-3  
NI DAQCard-6024E  
NI DAQCard-6036E  
NI DAQCard-6062E  
NI DAQCard-AI-16E-4  
NI DAQPad-6015  
NI DAQPad-6016  
NI DAQCard-AI-16XE-50  
NI DAQPad-6020E  
NI DAQPad-6052E  
NI DAQPad-6070E  
NI 6011E  
NI 6023E/6024E/6025E  
NI 6030E/6031E/6032E/6033E/6034E/6035E/6036E  
NI 6040E  
NI 6052E  
NI 6070E/6071E  
NI PCI-AI-16XE-10  
NI PCI-AI-64XE-10  
NI PCI-MIO-16E-1  
NI PCI-MIO-16E-4  
NI PCI-MIO-16XE-10  
NI PCI-MIO-16XE-50  
NI PCI-MIO-64E-1  
NI PCI-MIO-64XE-10  

M Series

Verification & Adjustment Verification Only
NI USB-6210/6211/6212/6215/6216/6218
NI 6220/6221/6224/6225/6229  
NI 6230/6232/6233/6236/6238/6239  
NI 6250/6251/6254/6255/6259  
NI 6280/6281/6284/6289  

R Series

Verification & Adjustment Verification Only
NI 7830R
NI 7831R  
NI 7833R  
NI 7841R  
NI 7842R  
NI 7851R  
NI 7852R  

S Series Devices

Verification & Adjustment Verification Only
NI 6110/6111/6115
NI 6120/6122/6123  
NI 6124  
NI 6132/6133  
NI 6143  
NI 6154  

X Series Devices

Verification & Adjustment Verification Only
NI 6320/6321/6323
NI 6341/6343  
NI 6351/6353/6356/6358  
NI 6361/6363/6366/6368  

High-Precision (Data Loggers)

Verification & Adjustment Verification Only
NI 4350/4351

DSA

Verification & Adjustment Verification Only
NI 4451/4452/4551/4552
NI 4461/4462  
NI 4472/4474/4472B  
NI 4495/4496/4498  

SC Series

Verification & Adjustment Verification Only
NI 4220

Counter/Timer Devices

Verification & Adjustment Verification Only
NI 6608 NI 6601
  NI 6602

Modular Instruments

DMM

Verification & Adjustment Verification Only
NI 4050
NI 4060  
NI 4065  
NI 4070  
NI 4071  
NI 4072  

High-Speed Digitizers

Verification & Adjustment Verification Only
NI 5102 NI 5112
NI 5105  
NI 5114  
NI 5122  
NI 5124  
NI 5132  
NI 5133  
NI 5142  
NI 5152  
NI 5153  
NI 5154  
NI 5185  
NI 5186  
NI 5620  
*NI 5622  
NI 5900  
NI 5911  
NI 5922  

High-Speed Digital I/O

Verification & Adjustment Verification Only
NI 6551
NI 6552  

Power Supplies & SMUs

Verification & Adjustment Verification Only
NI 4110
NI 4130  
NI 4132  

RF

Verification & Adjustment Verification Only
NI 5600 NI 5663/5663E
*NI 5601 NI 5673/5673E
NI 5610 NI PXI-5650 (191967J-01 and later)
*NI 5611 NI PXI-5651 (191967J-02 and later)
NI PXI-5650 (191967H-01 and earlier) NI PXI-5652 (191967J-03 and later)
NI PXI-5651 (191967H-02 and earlier) NI PXIe-5650
NI PXI-5652 (191967H-03 and earlier) NI PXIe-5651
  NI PXIe-5652

Signal Generators

Verification & Adjustment Verification Only
NI 5402 NI 5404
NI 5406  
NI 5412  
NI 5421  
NI 5422  
NI 5441  
NI 5442
*NI 5450  

PXI Timing and Synchronization

Verification & Adjustment Verification Only
NI 6652/6653
NI 6672

SCXI Modules

Verification & Adjustment Verification Only
SCXI-1102/B/C SCXI-1100
SCXI-1104/C  
SCXI-1120/D  
SCXI-1121  
SCXI-1124  
SCXI-1125  
SCXI-1520  
SCXI-1600  

*Support only available for components of the NI PXIe-5663 and PXIe-5673. No support for components of the NI PXIe-5663E and PXIe-5673E. See below for supported revisions by product. Product revision is in alphabetical order indicated by the letter immediately preceding the dash in the part number.

NI PXIe-5601        199080F-01L and earlier
NI PXIe-5610        196385D-01L and earlier
NI PXIe-5450        198643B-xxL and earlier
NI PXIe-5622        198941A-xxL and earlier

至页首

2. User Interface

The operator interface for Calibration Executive is shown in the series of images linked below.

Main operator interface
Setup wizard - customer information
Setup wizard - standards information
Setup wizard - device information
Example calibration report
Example calibration data

至页首

3. System Requirements

  • Windows XP (SP2)/7 (32-bit and 64-bit versions)
  • Pentium 4/M processor or equivalent
  • 2 GB of RAM
  • 1024 x 768 pixels screen resolution
  • The user must have administrator privileges

Note: Refer to the Calibration Executive Help for more information on Windows 7 support.

至页首

4. Calibration Executive Updates

The list above reflects the products supported in the latest version of Calibration Executive. If you are on an earlier version, and would like to search for  updates please visit the Drivers and Updates page at ni.com/downloads/ . To upgrade to the latest version of Calibration Executive, visit the model page here.

至页首

5. Additional Resources

View the List of Equipment Required to Calibrate NI Measurement Hardware