Overview

The National Instruments PXI/PXIe-2532 is a 512-crosspoint, high-speed matrix switch module. With the largest matrix size available in a 3U PXI slot, the NI PXI/PXIe-2532 offers ultrahigh-density switch configurations in PXI/PXIe. Several solutions are available for your signal connections. Terminal blocks provide connectivity to strain-relieved 0.050 in. pitch headers ideal for ribbon cable. Mass interconnect solutions are also available from industry leaders such as Virginia Panel and MAC Panel.

Table of Contents

  1. PXI/PXIe-2532 Terminal Blocks
  2. Expansion Options
  3. Signal Connection with Terminal Blocks
  4. Signal Connection with SCB-264x
  5. Mass Interconnect
  6. Related Links

1. PXI/PXIe-2532 Terminal Blocks

Several terminal blocks are available for the PXI/PXIe-2532:


Each terminal block can be ordered with or without column protection. To provide column protection the 0 ohm resistor in series with each column has been replaced by a 100 ohm resistor on the column connection board.


Column protection resistor



The TB-2640 and TB-2643 have 2 column connection boards.





PXI/PXIe-2532 terminal block with two column connection boards



The TB-2641, TB-2642, TB-2644, and TB-2645 have one column connection board.






PXI/PXIe-2532 with one column connection board

Back to Top

2. Expansion Options

To expand your matrix size use the 16-Pin Row Expansion Cable (part # 779325-01). This cable will allow you to connect rows of two adjacent PXI/PXIe-2532 terminal blocks to double the number of column. Since each terminal block offers two row connection header, multiple terminal blocks can be connected to create larger matrices.




PXI/PXIe-2532 matrix expansion

Back to Top

3. Signal Connection with Terminal Blocks

PXI/PXIe-2532 terminal blocks provide ribbon cable headers for column and row connection. There are two column headers per column connection board.

To connect signals to a column header you will need a 34 conductors 30 AWG, .05 in pitch ribbon cable connector and a 34 conductor, 30 AWG, .025 in. pitch shielded/unshielded ribbon cable.





Column ribbon cable header



Row ribbon cable header

 


Connectors and ribbon cable are available from different vendors.



Description
Manufacturer
Part number
16 Conductor, 30 AWG, .05 in. pitch
unshielded ribbon cable assembly
FFSD-08-01-N
34 Conductor, 30 AWG, .05 in. pitch
unshielded ribbon cable assembly
FFSD-17-01-N

PXI/PXIe-2532 terminal block accessories


To connect signals to any PXI/PXIe-2532 terminal blocks simply connect your cable assembly to the column and row headers:

Back to Top

4. Signal Connection with SCB-264x


The NI SCB-264X is a shielded connector block to interface individual signal wires to the rows and columns of the NI PXI/PXIe-2532 matrix. The NI SCB-264X has five ribbon cable connectors for connecting to the NI TB-2640/2641/2642/2643/2644 (NI TB-264X) connector blocks and screw terminals for connecting signals. The NI SCB-264X supports all NI PXI/PXIe-2532 topologies that are configured with the NI TB-264X. The NI SCB-264X can be used alone, or it can be rack-mounted using the included DIN rail-mounting kit. 

Note: References to the NI TB-264X in this document do not include the NI TB-2645. The NI TB-2645 is not compatible with the NI SCB-264X.

To connect the SCX-264X to any PXI/PXIe-2532 terminal blocks use the Row and Column Cable Kit (part# 779346-01).

This cable kit includes:

  • 1 16-conductors ribbon cable with connectors on both ends to connect the rows
  • 4 34-conductors ribbon cable with connectors on both ends to connect the columns






Back to Top

5. Mass Interconnect

Virginal Panel has been an important player in mass interconnect solutions for over 40 years with a high degree of reliability. They can offer a wide range of options for the PXI/PXIe-2532.





MAC Panel also provides configurable mass interconnect solutions including the SCOUT which offers PCB or short wire interconnections for your PXI/PXIe test system.  There are several options available for the PXI/PXIe-2532 that accommodate it's various topologies.

+ Enlarge Image

Back to Top

6. Related Links

KnowledgeBase 4QQH8D9G: How to Connect the TB-264x’s Columns to the SCB-264x

KnowledgeBase 4R3C2L9G: What Are the Optional Isolation Resistors of the TB-264x Series?

KnowledgeBase 4ZMH7M9G: Why Do I See Signal Attenuation With My PXI/PXIe-2532 Switch?