Overview

This document contains the LabWindows/CVI 2012 known issues that were discovered before and since the release of LabWindows/CVI 2012. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.

Each known issue includes these fields:

  • Issue ID
  • Legacy ID - The issue's legacy ID from NI's deprecated bug reporting database (if applicable)
  • Issue Title
  • Problem Description
  • Workaround
  • Reported Version - the earliest version of LabWindows/CVI the issue was reported in
  • Resolved Version - version the issue was resolved or was no longer applicable
  • Date Added - the date the issue was added to the document (not the reported date)

Modules and Toolkits

The Known Issues for toolkits and modules can be found in the LabWindows/CVI Modules and Toolkits Known Issues document.

Document Organization

The Known Issues Document is divided into two separate tables appearing in two separate Developer Zone documents. The known issues in this document are organized by the date they were added to this document. To view the issues organized by category, visit the document linked below:

Known Issues by Category

Contacting NI

You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. If you are contacting NI in regards to a specific issue, be sure to reference the ID number given in the document to the NI representative.

Known Issues by Date

The following items are known issues in LabWindows™/CVI 2012 sorted by Date.

126708 PlotArc lacks accuracy for drawing a small angle with a large radius.
128084 Uninstalling LabWindows/CVI from Windows Vista does not completely remove context menu file associations.
140926 Changing the axis range on a LabWindows/CVI graph plot with few points causes skewed plot lines.
144640 LabWindows/CVI MAX_PATHNAME_LEN is more restrictive than Windows ANSI path limitation in multibyte systems.
176800 LabWindows/CVI projects converted to Microsoft Visual C++ 2005 projects fail to build because of link errors.
186565 LabWindows/CVI distributions cannot install fonts on Windows Vista or Windows 7.
189843 The Perforce 2009.1 client may cause LabWindows/CVI 2009 to crash.
193088 If a LabWindows/CVI popup panel is not active, subsequent popup panels may appear behind the original popup panel.
193403 The panel attribute ATTR_MOVABLE does not work with Aero enabled on Windows 7/Vista.
193733 Launching the DataSocket Binding dialog box may cause LabWindows/CVI to hang on Windows 7.
194450 LabWindows/CVI windows do not support Aero Shake.
206504 Building debug versions of very large projects may cause LabWindows/CVI to run out of memory.
209745 Very large maximum stack sizes cause the "My Documents" button of LabWindows/CVI file select popup panels to fail.
210086 The LabWindows/CVI environment may hang while debugging with the Variables or Watch windows open.
41414 4DDCC0IO A small memory leak exists in network variable creation.
216549 LabWindows/CVI installs KeyHelp.ocx, which contains a security vulnerability.
236157 Opening a TDMS file that is at the same time open in another process can result in an error/
256901 Passing a pointer to a custom data type to a function that takes a void * will leak memory in a debug build.
256488 Duplicate "Could not expand variable" dialog boxes may display while debugging.
255342 Remote debugging can hang when debugging DLLs with DllMain.
257004 You cannot remote debug a multithreaded program with extended variable displays enabled.
257264 Watchpoints might not be able to run after manually suspending a multithreaded program.
237998 Cannot link some uuid.lib symbols in a 32-bit program.
257397 Debugging a multithreaded real-time program with watchpoints may cause the real-time target to hang.
44669 4HK7LF7K The WordRpt_SetHeader function might not always work as expected.
285461 Attaching the LabWindows/CVI debugger to a C++ DLL might result in significant performance degradation.
283594 clang does not recognize the _export and _import qualifiers.
284771 When using third-party compilers, linker errors refer to temporary object files.
284293 Using a WebBrowser ActiveX control from a thread created in a LabWindows/CVI thread pool leaks memory.
277739 Compiling a file with a syntax error can cause LabWindows/CVI to crash.
281013 Calling DDC_SaveFile often while creating a TDMS file using the TDM C DLL or the DDC Library can result in errors.
227324 LabWindows/CVI cannot copy files to the VXIPnP directories on Windows Vista and later.
255345 TDMS_CloseFile can take a long time to complete when the LabWindows/CVI debugger is attached.
257029 The LabWindows/CVI Run-Time Engine creates windows in its DLL_PROCESS_ATTACH handler.
289949 Using an import library generated by MinGW results in "Bad COFF Library Member Header" error message.
289314 User-defined types always receive an asterisk when used as output types in function panels.
303637 Scrolling strip charts can have inaccurate values for min and max due to rounding errors.
304359 Attaching to a process that loads a debuggable LabWindows/CVI DLL can result in LabWindows/CVI crashing if you open an unrelated project after debugging the process.
306163 The PeakDetector function does not recognize peaks of a sine wave when the sampling rate is very high.
306206 The clang external compiler does not correctly handle the long double data type.
298025 Setting the inputMode parameter of SetInputMode to 0 blocks user interaction when events are processed, not when the user interacts with the UI.
309112 LabWindows/CVI 8.0 distributions cannot include the ActiveX container merge module if LabWindows/CVI 2009 or later is installed on the same system.
295246 A source file containing a very large array of structures might fail to compile.
296666 Regenerating DAQmx example code can sometimes fail to regenerate code.
293672 Some user interface controls do not draw Windows styles on mouse-over.
257160 The LabWindows/CVI debugger can hang when LoadPanel fails in a DLL with variables expanded using the Specific Type option in the Variables window.
291945 Compiling a very large array in debug mode can be very slow.
292070 Passing TRUE to the RestrictDirectory parameter of FileSelectPopup does not completely restrict the directory to the initial directory.
37498 44K3HK07 Variables defined inside of a block statement cannot be added to the Watch window.
37666 3TJ0IB7K Panels displayed with ATTR_WINDOW_ZOOM set to VAL_MAXIMIZE will not restore after showing the desktop.
329035 LabWindows/CVI Conversion Wizard does not transfer 'Compile with precompiled include file' setting to 'Precompiled Headers' setting in Microsoft Visual Studio.
331932 Partially selecting an attribute value in the Attribute Browser and then resizing the Attribute Browser causes the entire text in that field to be selected.
326106 If you save UIR files as older versions, LabWindows/CVI does not warn you that features that are unsupported in that version will not be saved.
332047 LabWindows/CVI stops responding while searching for an inaccessible network location.
314106 The x-axis of the digital graph displays improper divisions.
311364 Function name displays twice in the function prototype tooltip when the return value is const or volatile.
322979 Drawing a filled shape on the canvas with a pen width greater than 1 causes the filling to exceed the shape's border.
344028 Program can hang when a graph or strip chart is on screen and axis labels are visible
333163 The Choose Date/Time Value dialog box displays an error message for an invalid date three times.
334992 Watch expressions become inactive after switching configurations.
316397 Saving a file with the FileSelectPopup function displays a "file already exists" error when another file with the same basename and no extension exists in the selected directory.
322905 Files in a project may not display source control icons when a LabWindows/CVI project is associated with the Perforce client.
333571 Moving selected text in the Source window and then undoing offsets the original cursor position.
333837 LabWindows/CVI projects are not handled properly when adding them from new workspaces in instances of LabWindows/CVI created from just-in-time debugging.
334920 Corners of Source Editor windows are painted black in non-tabbed Workspace when opened.
329405 Numeric control radix does not resize with control text size.
335405 Cannot link some odbccp32.lib symbols in a 32-bit program.
335982 MultiFileSelectPopupEx cannot select multiple files if the first file in the list does not exist and the second file does.
351981 Dimming ActiveX control does not terminate mouse tracking.
357212 The save icon does not dim after saving a file.
359402 Third-party compilers do not enable C99 extensions even if you enable the Build with C99 extensions option in the Build Options dialog box.
360351 NI Automotive Diagnostic Command Set and NI ECU Measurement and Calibration Toolkit cannot be activated through NI License Manager.
362376 The Programmer's Toolbox function ListCreate leaks memory.
360485 Passing NULL to SingleToneSignal for the searchType input parameter causes a fatal run-time error.
360745 Cannot launch the LabWindows/CVI Help from the Help menu when a help tooltip is visible.
361054 Attribute not valid error when auto-declaring a variable from ANSI C Library Formatted Input/Output functions such as printf or sprintf.
361327 The CNVGetScalarDataValue function expects a char* only and not a char[ ] as described in the function help.
361958 The Project Tree does not auto-hide when a UIR file is opened.
362123 Gamma, GammaC, and Beta functions compute regularized form, which is not accurately described in help.
362403 Saving a copy of the UIR as an older version causes the currently loaded copy to switch to that version.
363056 Floating point format in UI controls allows too many digits before automatically switching to scientific format.
363196 Attribute passed is not valid error when declaring a variable in a function panel.
363456 Compiler warning when using __int64 in switch statement expression in a 32-bit configuration.
353320 Attempting to edit a "??" entry in the Memory window causes an error.
354449 Very long strings in the Edit Distributions dialog box may crash LabWindows/CVI.
356348 Using the TCP Library from multiple threads may cause a deadlock when combined with locks in the user's TCP callbacks.
361691 The GetAllBreakpoints LabWindows/CVI ActiveX Server Interface function does not set numBreakpoints output parameter.
361840 For values of x that are very large, sin (x) returns x instead of returning a number between -1 and 1.
337950 Graph zoom selection box leaves artifacts if a control is moved over the drawing region in between frames.
339884 When allocating memory with malloc, LabWindows/CVI will truncate the memory allocated to be an integer multiple of the size of the pointer data type.
340055 Breakpoints may be missed when attaching to a non-debuggable process that calls a debuggable DLL in multiple threads.
345703 Some controls do not print colors correctly in bitmap printing when set to black & white mode.
347056 Dragging the ring tank control value to change its fluid height at run-time may cause black lines to appear where the previous fluid height was.
347323 Changing digital graph line label and bus label programmatically does not update the control labels if the plot does not contain any data.
347511 Microsoft Visual Studio does not rebuild a LabWindows/CVI project if a UIR file changes but its header file does not.
347986 The Load UI resource file dialog box in the User Interface Localizer utility unloads the currently loaded localization.
348295 A panel containing an ActiveX control disappears when the mouse hovers over the control if the titlebar is not visible.
349832 The mouse wheel scrolls the wrong control while ring control menu is displayed.
350412 In some cases, the EVENT_LOST_FOCUS and EVENT_COMMIT events are not displayed in Operate mode when changing focus away from controls.
350752 A tree item tooltip continues to display when the cursor is over a tree item and another active window is in front of part of the tree item.
350944 The numeric control cannot have a transparent background.
351155 LoadExternalModule does not guarantee that the module loaded is 16-byte aligned.
352408 Pressing F1 on a function in the ActiveX Library or most of the Tools Libraries does not open the LabWindows/CVI Help to the topic for the specified function.
354450 Using a very long string when setting the value of a variable in the Variables window may crash the LabWindows/CVI environment.
354451 A very long string value in the Add/Edit Tools Menu Item dialog box may crash LabWindows/CVI.
354452 A very long string value in the Project folder or File Folder option of the New Project from Template or New File from Template dialog boxes may crash LabWindows/CVI.
354481 User specified icons are not displayed in Windows Explorer for larger sizes in Windows Vista/7.
355331 Editing the RGB values of an RGB color in the Watch window doesn't also update the overall value of the variable in the parent node.
356421 Entries in the Watch window may be dimmed incorrectly if multiple entries have the same symbol name.
356470 Building the sdk\stdio\demo.prj example project in a 64-bit configuration against the clang compiler causes an unrecoverable internal error.
356708 The Source window cursor can persist after selecting text and editing a variable tooltip.
357245 Local array in a thread that has exited may appear as still active in the Watch window.
358560 Function name is not reported in Break On Library Errors message.
359304 The modulo operation with 64-bit integers in a 32-bit configuration may produce incorrect results.
360314 The LabWindows/CVI environment crashes when showing a time_t variable in the Watch or Variables window while debugging a 64-bit application with extended debugging enabled.
335983 Tooltip for symbol values during debugging may appear on top of the editor's scrollbar.
337770 Setting LabWindows/CVI to "Run as administrator" will open a new instance of LabWindows/CVI each time you open a file associated with LabWindows/CVI.
333302 Auto Backup will provide an error if the file is marked as read-only.
335488 Excluded import libraries that represent both 32-bit and 64-bit .lib files are no longer dimmed after switching configurations.
339287 The Default index for combo box cell types in the Edit Table dialog box expands too far down if the value has multiple lines.
364220 Welcome Page PDF links do not work unless you are using Adobe Acrobat.
309845 Tree control tooltip does not use the character set of the tree.
362404 The LabWindows/CVI Run-Time Engine displays incorrectly in LabVIEW Application Builder and TestStand Deployment Utility.



ID Known Issue
126708

Return
PlotArc lacks accuracy for drawing a small angle with a large radius.

Workaround: N/A

Reported Version: 8.5.1    Resolved Version: N/A    Added: 05/05/2010
128084

Return
Uninstalling LabWindows/CVI from Windows Vista does not completely remove context menu file associations.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 05/05/2010
140926

Return
Changing the axis range on a LabWindows/CVI graph plot with few points causes skewed plot lines.
Due to rounding errors, as points move further off screen, the plot lines become less accurate.

Workaround: Provide more points for your plot, or constrain the range of the graph in question.

Reported Version: 5.5    Resolved Version: N/A    Added: 05/05/2010
144640

Return
LabWindows/CVI MAX_PATHNAME_LEN is more restrictive than Windows ANSI path limitation in multibyte systems.

Workaround: N/A

Reported Version: 7.1.1    Resolved Version: N/A    Added: 05/05/2010
176800

Return
LabWindows/CVI projects converted to Microsoft Visual C++ 2005 projects fail to build because of link errors.
Link errors such as
cvisupp.lib(setprec.obj) : fatal error LNK1103: debugging information corrupt; recompile module
and
cviauto.lib(implib.obj) : fatal error LNK1103: debugging information corrupt; recompile module
are indications your projects are affected by this problem.

Workaround: Apply the VS2005 SP1 hotfix included for KB949009.

Reported Version: 2009    Resolved Version: N/A    Added: 05/05/2010
186565

Return
LabWindows/CVI distributions cannot install fonts on Windows Vista or Windows 7.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 05/05/2010
189843

Return
The Perforce 2009.1 client may cause LabWindows/CVI 2009 to crash.
LabWindows/CVI may crash when the Perforce SCC DLL is unloaded.

Workaround: Upgrade to the Perforce 2009.2 client.

Reported Version: 8.1    Resolved Version: N/A    Added: 05/05/2010
193088

Return
If a LabWindows/CVI popup panel is not active, subsequent popup panels may appear behind the original popup panel.
This issue only occurs on Windows 7/Vista.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 05/05/2010
193403

Return
The panel attribute ATTR_MOVABLE does not work with Aero enabled on Windows 7/Vista.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 05/05/2010
193733

Return
Launching the DataSocket Binding dialog box may cause LabWindows/CVI to hang on Windows 7.

Workaround: Switch away from LabWindows/CVI to another application, and then switch back to LabWindows/CVI.

Reported Version: 2009    Resolved Version: N/A    Added: 05/05/2010
194450

Return
LabWindows/CVI windows do not support Aero Shake.
Shaking the title bar of the LabWindows/CVI environment or LabWindows/CVI panels or pressing <Windows-Home> when a LabWindows/CVI window is active does not minimize other open windows. When Aero is enabled in Windows 7, the other windows should be minimized by the Aero Shake feature.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 05/05/2010
206504

Return
Building debug versions of very large projects may cause LabWindows/CVI to run out of memory.

Workaround: Right-click files that do not need to be debugged and select Enable 'O' Option. This option removes debugging information from the compiled object file, resulting in a much smaller memory footprint.

Reported Version: 9.0    Resolved Version: N/A    Added: 05/05/2010
209745

Return
Very large maximum stack sizes cause the "My Documents" button of LabWindows/CVI file select popup panels to fail.
After you click the My Documents button, only a white background displays. Your drives and network locations will not display.

Workaround: Reduce the maximum stack size.

Reported Version: 2009    Resolved Version: N/A    Added: 05/05/2010
210086

Return
The LabWindows/CVI environment may hang while debugging with the Variables or Watch windows open.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 05/05/2010
41414
4DDCC0IO


Return
A small memory leak exists in network variable creation.
Explicitly creating network variables results in a memory leak of approximately 50 bytes per variable that is created.

Workaround: Consider using implicitly created network variables if you are creating and deleting numerous network variables over a long period of time.

Reported Version: 8.5    Resolved Version: N/A    Added: 05/05/2010
216549

Return
LabWindows/CVI installs KeyHelp.ocx, which contains a security vulnerability.
For more information, refer to this link.

Workaround: This component is used for help tooltips in the LabWindows/CVI User Interface Editor. It can be safely prevented from being used in IE by using the Microsoft kill bit mechanism. The CLSID for this control is {16DDBCA2-9F0B-4927-9315-62D8893FC7E8}.

Reported Version: 2009 SP1    Resolved Version: N/A    Added: 09/17/2010
236157

Return
Opening a TDMS file that is at the same time open in another process can result in an error/
This issue occurs even if the file is opened in read-only mode.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 09/17/2010
256901

Return
Passing a pointer to a custom data type to a function that takes a void * will leak memory in a debug build.
LabWindows/CVI user protection leaks memory when a pointer to a user defined data type is passed to a function with a void * parameter. An example of this would be calling the function ListInsertItem and passing a pointer to a user defined data type to the PointerToItem parameter.

Workaround: Disable user protection, or build the program in a Release configuration.

Reported Version: 9.0    Resolved Version: N/A    Added: 11/15/2010
256488

Return
Duplicate "Could not expand variable" dialog boxes may display while debugging.
If you step over code while a watchpoint is expanded, you may see multiple "Could not expand variable" dialog boxes.

Workaround: Disable extended Variables/Watch window displays.

Reported Version: 2009    Resolved Version: N/A    Added: 11/17/2010
255342

Return
Remote debugging can hang when debugging DLLs with DllMain.

Workaround: Move DllMain to a source code module that is not compiled with debug info.

Reported Version: 8.0    Resolved Version: N/A    Added: 11/18/2010
257004

Return
You cannot remote debug a multithreaded program with extended variable displays enabled.

Workaround: Disable the Enable extended Variables/Watch window displays option in the Environment dialog box.

Reported Version: 2009    Resolved Version: N/A    Added: 11/18/2010
257264

Return
Watchpoints might not be able to run after manually suspending a multithreaded program.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 11/18/2010
237998

Return
Cannot link some uuid.lib symbols in a 32-bit program.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 11/22/2010
257397

Return
Debugging a multithreaded real-time program with watchpoints may cause the real-time target to hang.
The watchpoints must be in update continuously mode or set to break when the value changes.

Workaround: Disable Update display continuously and Break when value changes for watchpoints.

Reported Version: 2009    Resolved Version: N/A    Added: 11/22/2010
44669
4HK7LF7K


Return
The WordRpt_SetHeader function might not always work as expected.
Embedding pictures in a header does not work.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 11/22/2010
285461

Return
Attaching the LabWindows/CVI debugger to a C++ DLL might result in significant performance degradation.
If you are debugging a process that calls into a C++ DLL, significant performance degradation might occur. This performance degradation has occurred for C++ DLLs that throw many exceptions or create and destroy large STL maps.

Workaround: There is no workaround while debugging, but there is no performance degradation while running outside of the LabWindows/CVI debugger.

Reported Version: 7.0    Resolved Version: N/A    Added: 03/03/2011
283594

Return
clang does not recognize the _export and _import qualifiers.

Workaround: Use __declspec(dllexport) and __declspec(dllimport) instead.

Reported Version: 2010    Resolved Version: N/A    Added: 03/04/2011
284771

Return
When using third-party compilers, linker errors refer to temporary object files.
If link errors are found for multiple modules, the link errors will all be reported in the same temporary object file.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 03/04/2011
284293

Return
Using a WebBrowser ActiveX control from a thread created in a LabWindows/CVI thread pool leaks memory.
Threads from a LabWindows/CVI thread pool, run using CmtScheduleThreadPoolFunction, will leak memory if they host a panel that displays a WebBrowser ActiveX control.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 03/08/2011
277739

Return
Compiling a file with a syntax error can cause LabWindows/CVI to crash.
A very specific type of syntax error can cause LabWindows/CVI to crash. For example, compiling a file that contains the following code will cause LabWindows/CVI to crash.

void a(b, int c) { int d = b; }

Workaround: Remove the syntax error before recompiling.

Reported Version: 5.0    Resolved Version: N/A    Added: 03/09/2011
281013

Return
Calling DDC_SaveFile often while creating a TDMS file using the TDM C DLL or the DDC Library can result in errors.
Depending on when DDC_SaveFile is called, you might receive error -6218 or error -6226.

Workaround: Don't call DDC_SaveFile until all operations are complete.

Reported Version: 2010    Resolved Version: N/A    Added: 03/09/2011
227324

Return
LabWindows/CVI cannot copy files to the VXIPnP directories on Windows Vista and later.
These directories are locked by default, which is not the correct behavior.

Workaround: Install VISA, which will unlock these directories.

Reported Version: 2009    Resolved Version: N/A    Added: 03/10/2011
255345

Return
TDMS_CloseFile can take a long time to complete when the LabWindows/CVI debugger is attached.
If your TDMS file contains many channels, a call to TDMS_CloseFile can take a very long time. The more channels you have, the longer the call can take. This occurs only when the LabWindows/CVI debugger is attached. This is related to Known Issue 285461.

Workaround: N/A

Reported Version: 8.1    Resolved Version: N/A    Added: 03/10/2011
257029

Return
The LabWindows/CVI Run-Time Engine creates windows in its DLL_PROCESS_ATTACH handler.
When the LabWindows/CVI Run-Time Engine loads, it creates multiple windows in its DLL_PROCESS_ATTACH handler. This is generally discouraged practice, but has not been known to cause problems in user applications.

Workaround: Do not call the Win32 API functions LoadLibrary and FreeLibrary to load and unload a LabWindows/CVI built DLL from different threads.

Reported Version: 2009    Resolved Version: N/A    Added: 03/10/2011
289949

Return
Using an import library generated by MinGW results in "Bad COFF Library Member Header" error message.

Workaround: Open the header file that contains the function prototypes for the DLL in LabWindows/CVI. Then use the Options»Generate DLL Import Library menu item to generate an import library for the DLL.

Reported Version: 8.5    Resolved Version: N/A    Added: 03/21/2011
289314

Return
User-defined types always receive an asterisk when used as output types in function panels.
For instance, if you define a custom type as
typedef char[256] String255;
you would not want it to have an asterisk appended to it when used as an output type.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 03/24/2011
303637

Return
Scrolling strip charts can have inaccurate values for min and max due to rounding errors.
For example, if your strip chart displays 100 points and you plot 100 points at a time, the end values may end with a value other than 99.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 07/27/2011
304359

Return
Attaching to a process that loads a debuggable LabWindows/CVI DLL can result in LabWindows/CVI crashing if you open an unrelated project after debugging the process.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/27/2011
306163

Return
The PeakDetector function does not recognize peaks of a sine wave when the sampling rate is very high.
If the peak is relatively flat because of the high number of points acquired at the high sampling rate, the PeakDetector function may not find the peaks.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/27/2011
306206

Return
The clang external compiler does not correctly handle the long double data type.
All long double variables will have a value of 0.

Workaround: Use double instead of long double.

Reported Version: 2010    Resolved Version: N/A    Added: 07/27/2011
298025

Return
Setting the inputMode parameter of SetInputMode to 0 blocks user interaction when events are processed, not when the user interacts with the UI.
This can be seen by calling SetInputMode(...,...,0) inside a callback function, delaying for one second, and then calling SetInputMode(...,...,1) before exiting the callback function. If you click the dimmed button during the 1 second delay, that click event will be processed the next time events are processed by the LabWindows/CVI Run-Time Engine.

Workaround: Ensure that events are being processed when the inputMode parameter of SetInputMode to is set to 0.

Reported Version: 3.0    Resolved Version: N/A    Added: 07/28/2011
309112

Return
LabWindows/CVI 8.0 distributions cannot include the ActiveX container merge module if LabWindows/CVI 2009 or later is installed on the same system.
This issue occurs because the name of the merge module changed in LabWindows/CVI 2009, and LabWindows/CVI 8.0.x attempted to find merge modules by name.

Workaround: Create a copy of C:\Program Files (x86)\Common Files\Merge Modules\ActiveX_Container.msm and rename the copy to C:\Program Files (x86)\Common Files\Merge Modules\ActiveX Container.msm.

Reported Version: 2009    Resolved Version: N/A    Added: 07/28/2011
295246

Return
A source file containing a very large array of structures might fail to compile.
For example, if you declare an array of 5000000 NIComplexNumber structures, LabWindows/CVI will fail to compile the file without any error message.

Workaround: Either:
  • Set the Debugging level option (Options»Build Options) to No run-time checking.
  • Define the array in a new source file. Right-click the new source file in the project tree and select Enable .Obj Option.


Reported Version: 8.1    Resolved Version: N/A    Added: 07/30/2011
296666

Return
Regenerating DAQmx example code can sometimes fail to regenerate code.
If you change acquisition mode from "Every N Samples" to "Continuous Samples", the example code may not regenerate.

Workaround: Regenerate the code from the source file instead of the header file.

Reported Version: 2010    Resolved Version: N/A    Added: 07/30/2011
293672

Return
Some user interface controls do not draw Windows styles on mouse-over.
For example, the following controls and control parts should display as a highlighted blue on Windows Vista and later, but do not:
  • The inc/dec arrows for all numeric controls.
  • The square push button and the square text button.
  • The list control scroll bar arrows and thumb.


Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 08/01/2011
257160

Return
The LabWindows/CVI debugger can hang when LoadPanel fails in a DLL with variables expanded using the Specific Type option in the Variables window.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 08/02/2011
291945

Return
Compiling a very large array in debug mode can be very slow.
For instance, compilation of the following code in debug mode would be very slow:

char *bigarray[30][25][1000][100];
int main (int argc, char *argv[]) { return 0; }


Workaround: Change the Debugging level option (Options»Build Options) to No run-time checking.

Reported Version: 2010    Resolved Version: N/A    Added: 08/02/2011
292070

Return
Passing TRUE to the RestrictDirectory parameter of FileSelectPopup does not completely restrict the directory to the initial directory.
The user can select files from other directories by entering the path directly into the File Name control and by selecting a file from the previously selected files drop-down list.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 08/02/2011
37498
44K3HK07


Return
Variables defined inside of a block statement cannot be added to the Watch window.
For instance the variable a in the following code cannot be added to the Watch window.

void foo (int var)
  if (var == 0) {
    int a;
    a = var;
  }
}


Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 08/02/2011
37666
3TJ0IB7K


Return
Panels displayed with ATTR_WINDOW_ZOOM set to VAL_MAXIMIZE will not restore after showing the desktop.
You can show the desktop by pressing <Windows Key-D> or by selecting the Show Desktop button on the task bar.

Workaround: Call SetPanelAttribute with ATTR_WINDOW_ZOOM after calling DisplayPanel.

Reported Version: 8.0    Resolved Version: N/A    Added: 08/02/2011
329035

Return
LabWindows/CVI Conversion Wizard does not transfer 'Compile with precompiled include file' setting to 'Precompiled Headers' setting in Microsoft Visual Studio.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 01/09/2012
331932

Return
Partially selecting an attribute value in the Attribute Browser and then resizing the Attribute Browser causes the entire text in that field to be selected.
N/A

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 01/09/2012
326106

Return
If you save UIR files as older versions, LabWindows/CVI does not warn you that features that are unsupported in that version will not be saved.
When saving a UIR file as an older version, LabWindows/CVI does not warn you that some features that were not supported in that version will not be saved. These features cannot be saved because they did not exist in that version.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 01/10/2012
332047

Return
LabWindows/CVI stops responding while searching for an inaccessible network location.
When LabWindows/CVI is searching for a file at a network location that is not available, the environment stops responding.

Workaround: The search times out after about 2 minutes and the environment will resume. Avoid attempts to access network locations that may not be available.

Reported Version: 8.5.1    Resolved Version: N/A    Added: 01/10/2012
314106

Return
The x-axis of the digital graph displays improper divisions.
Large digital graphs with engineering or scientific display format set for the x-axis may display divisions and division labels that are inconsistent with other display formats.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 01/11/2012
311364

Return
Function name displays twice in the function prototype tooltip when the return value is const or volatile.
N/A

Workaround: N/A

Reported Version: 7.0    Resolved Version: N/A    Added: 02/06/2012
322979

Return
Drawing a filled shape on the canvas with a pen width greater than 1 causes the filling to exceed the shape's border.
When the pen width for a canvas is greater than 1 and you specify VAL_DRAW_FRAME_AND_INTERIOR as the Draw Mode for the draw function, the filling will exceed the shape's border.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 02/09/2012
344028

Return
Program can hang when a graph or strip chart is on screen and axis labels are visible
For this problem to occur at least one axis label must visible. When label strings get too close to the edge of the control, they will attempt to reposition themselves inward to avoid being cut off, but in some cases the repositioning algorithm will reposition to the same value and cycle endlessly. On Linux this problem can manifest itself as a hang that requires you to end the process. This problem is most likely to occur with one of the x-axis label strings if the x-axis has negative values or ATTR_FIXED_PLOT_AREA is enabled and ATTR_PLOT_AREA_LEFT is set too close to the edge.

Workaround: There are two workarounds: 1) Disable the axis label string. 2) Enable ATTR_FIXED_PLOT_AREA and then set ATTR_PLOT_AREA_LEFT (if the problem is happening with the left x-axis) to a value a few pixels over to the right until the problem stops occurring. The value this needs to be set to is dependent on the font and min/max of the affected scale so a precise value can't be given.

Reported Version: 2010    Resolved Version: N/A    Added: 02/09/2012
333163

Return
The Choose Date/Time Value dialog box displays an error message for an invalid date three times.
If you enter an invalid date, such as Febuary 31, in the Choose Date/Time Value dialog box, LabWindows/CVI closes the dialog box and its parent dialog boxes and displays an error message stating Value is invalid or out of range three times.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 02/14/2012
334992

Return
Watch expressions become inactive after switching configurations.
Watch expressions are tied to a specific executable or DLL. If the target settings for two different configurations point to different paths, then the watch expression cannot be shared between the two configurations.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 02/14/2012
316397

Return
Saving a file with the FileSelectPopup function displays a "file already exists" error when another file with the same basename and no extension exists in the selected directory.
The file is saved despite the error.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 02/15/2012
322905

Return
Files in a project may not display source control icons when a LabWindows/CVI project is associated with the Perforce client.
If the Perforce Workspace root path has different casing than the actual path, then the icons do not display.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 02/15/2012
333571

Return
Moving selected text in the Source window and then undoing offsets the original cursor position.
Selecting text and dragging it in a Source window moves the text to the new location. However, when this operation is undone, the input cursor is not restored to the correct location even though the text is still highlighted.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 02/15/2012
333837

Return
LabWindows/CVI projects are not handled properly when adding them from new workspaces in instances of LabWindows/CVI created from just-in-time debugging.
Adding or removing a project from the Project Tree in an instance of LabWindows/CVI created by the just-in-time debugger can cause unexpected behavior.

Workaround: Do not add projects to the Project from instances of LabWindows/CVI created by the just-in-time debugger.

Reported Version: 2010    Resolved Version: N/A    Added: 02/15/2012
334920

Return
Corners of Source Editor windows are painted black in non-tabbed Workspace when opened.
When opening a workspace that has the Show Tabbed Workspace option disabled and at least one source code window open, the top corners of the Source Editor windows are painted black.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 02/15/2012
329405

Return
Numeric control radix does not resize with control text size.
N/A

Workaround: N/A

Reported Version: 3.0    Resolved Version: N/A    Added: 03/23/2012
335405

Return
Cannot link some odbccp32.lib symbols in a 32-bit program.
The issue exists with the odbccp32.lib that is included in the Windows 7 SDK.

Workaround: Use odbccp32.lib from the Windows Vista SDK instead.

Reported Version: 2010    Resolved Version: N/A    Added: 07/17/2012
335982

Return
MultiFileSelectPopupEx cannot select multiple files if the first file in the list does not exist and the second file does.
The selection error occurs only if the first file in the selection list does not exist and an existing file appears later in the list.

Workaround: Ensure that the first file in the selection list exists.

Reported Version: 2012    Resolved Version: N/A    Added: 07/17/2012
351981

Return
Dimming ActiveX control does not terminate mouse tracking.
This behavior can cause problems if you dim the ActiveX control while doing a click and drag operation on the control. In this scenario, the mouse interaction continues even after the control is dimmed.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/17/2012
357212

Return
The save icon does not dim after saving a file.
After a file is saved, the save icon is not dimmed. Once you click anywhere in the LabWindows/CVI editor after saving, the icon will then dim.

Workaround: N/A

Reported Version: 2012    Resolved Version: N/A    Added: 07/17/2012
359402

Return
Third-party compilers do not enable C99 extensions even if you enable the Build with C99 extensions option in the Build Options dialog box.
This behavior can cause problems in some LabWindows/CVI headers that require _CVI_C99_EXTENSIONS_ to be defined.

Workaround: In the Advanced Compiler Options dialog box for the third party setup, add -D_CVI_C99_EXTENSIONS_=1 to the C99 Flags field. While this flag is enabled, the C99 extensions checkbox will work for this third party compiler.

Reported Version: 2010    Resolved Version: N/A    Added: 07/17/2012
360351

Return
NI Automotive Diagnostic Command Set and NI ECU Measurement and Calibration Toolkit cannot be activated through NI License Manager.

Workaround: Activate the toolkit through the NI Activation Wizard in LabWIndows/CVI. To launch the NI Activation Wizard, click the Activate Products button in the LabWindows/CVI Message that displays when you launch LabWindows/CVI.

Reported Version: 2012    Resolved Version: N/A    Added: 07/17/2012
362376

Return
The Programmer's Toolbox function ListCreate leaks memory.
The memory leak occurs only in a debug build.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/17/2012
360485

Return
Passing NULL to SingleToneSignal for the searchType input parameter causes a fatal run-time error.

Workaround: Pass an invalid input instead.

Reported Version: 2010    Resolved Version: N/A    Added: 07/18/2012
360745

Return
Cannot launch the LabWindows/CVI Help from the Help menu when a help tooltip is visible.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/18/2012
361054

Return
Attribute not valid error when auto-declaring a variable from ANSI C Library Formatted Input/Output functions such as printf or sprintf.
The error occurs only when auto-declaring the Target String or the Format String. The error can be ignored.

Workaround: N/A

Reported Version: 2012    Resolved Version: N/A    Added: 07/18/2012
361327

Return
The CNVGetScalarDataValue function expects a char* only and not a char[ ] as described in the function help.

Workaround: N/A

Reported Version: 8.1    Resolved Version: N/A    Added: 07/18/2012
361958

Return
The Project Tree does not auto-hide when a UIR file is opened.
Other file types do auto-hide the Project Tree. This behavior occurs only if you enable the Auto hide Project Tree and Library Tree option in the Environment dialog box.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 07/18/2012
362123

Return
Gamma, GammaC, and Beta functions compute regularized form, which is not accurately described in help.
The Gamma function actually computes the gamma function or the regularized incomplete gamma function. The GammaC function computes the regularized complimentary incomplete gamma function. The Beta function computes the beta function or the regularized incomplete beta function.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/18/2012
362403

Return
Saving a copy of the UIR as an older version causes the currently loaded copy to switch to that version.
Using the Save Copy of UIR As option will create a copy of the UIR in the specified version. However, the currently loaded UIR also changes to the specified version. If the UIR is then saved, it is saved as the earlier version.

Workaround: Close the current UIR without saving changes. Reopen the UIR, and it will be in the correct version.

Reported Version: 2009    Resolved Version: N/A    Added: 07/18/2012
363056

Return
Floating point format in UI controls allows too many digits before automatically switching to scientific format.
The floating point representation may show more digits than are represented by the underlying data.

Workaround: Use scientific format if you may need to display very large numbers.

Reported Version: 6.0    Resolved Version: N/A    Added: 07/18/2012
363196

Return
Attribute passed is not valid error when declaring a variable in a function panel.
The error is incorrectly displayed and can be ignored.

Workaround: N/A

Reported Version: 2012    Resolved Version: N/A    Added: 07/18/2012
363456

Return
Compiler warning when using __int64 in switch statement expression in a 32-bit configuration.
"Warning: Conversion from '__int64' to 'long' might lose data" can occur if the switch expression is of type __int64 and all of the case expressions are of type int or long. The conversion does not actually occur and the warning can be ignored.

Workaround: N/A

Reported Version: 7.0    Resolved Version: N/A    Added: 07/18/2012
353320

Return
Attempting to edit a "??" entry in the Memory window causes an error.
In LabWindows/CVI 2009 and earlier the error is "Cannot write to address <address*gt;" and then the ADE may crash. In LabWindows/CVI 2010 and later, the error is "A custom control callback has raised an exception" and the ADE does not crash.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/20/2012
354449

Return
Very long strings in the Edit Distributions dialog box may crash LabWindows/CVI.
Many of the text fields in the Edit Distributions dialog boxes do not have string length limits. Strings that are too long for the field may cause the ADE to crash.

Workaround: Limit the Application Name to 50 characters, the registry keys relative paths to 255 characters, and registry values to 2048 characters.

Reported Version: 8.5    Resolved Version: N/A    Added: 07/20/2012
356348

Return
Using the TCP Library from multiple threads may cause a deadlock when combined with locks in the user's TCP callbacks.

Workaround: N/A

Reported Version: 7.0    Resolved Version: N/A    Added: 07/20/2012
361691

Return
The GetAllBreakpoints LabWindows/CVI ActiveX Server Interface function does not set numBreakpoints output parameter.
The variable remains uninitialized after the function call if it was not initialized before.

Workaround: Use the length of the breakpoint line numbers safearray output parameter.

Reported Version: 8.1    Resolved Version: N/A    Added: 07/20/2012
361840

Return
For values of x that are very large, sin (x) returns x instead of returning a number between -1 and 1.
This behavior occurs only for large values of x, such as 1e+20.

Workaround: N/A

Reported Version: 7.0    Resolved Version: N/A    Added: 07/20/2012
337950

Return
Graph zoom selection box leaves artifacts if a control is moved over the drawing region in between frames.
If a control is moved over the graph's drawing region while creating a zoom selection box, the control may interfere with the drawing of the selection box and leave traces of where the selection box once was.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
339884

Return
When allocating memory with malloc, LabWindows/CVI will truncate the memory allocated to be an integer multiple of the size of the pointer data type.
You cannot allocate a large memory block and then manually split it into smaller blocks. If you do, you may receive run-time errors.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 07/22/2012
340055

Return
Breakpoints may be missed when attaching to a non-debuggable process that calls a debuggable DLL in multiple threads.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/22/2012
345703

Return
Some controls do not print colors correctly in bitmap printing when set to black & white mode.

Workaround: N/A

Reported Version: 8.1    Resolved Version: N/A    Added: 07/22/2012
347056

Return
Dragging the ring tank control value to change its fluid height at run-time may cause black lines to appear where the previous fluid height was.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 07/22/2012
347323

Return
Changing digital graph line label and bus label programmatically does not update the control labels if the plot does not contain any data.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/22/2012
347511

Return
Microsoft Visual Studio does not rebuild a LabWindows/CVI project if a UIR file changes but its header file does not.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/22/2012
347986

Return
The Load UI resource file dialog box in the User Interface Localizer utility unloads the currently loaded localization.
If changes have been made in the loaded file, a dialog box prompts you to save.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/22/2012
348295

Return
A panel containing an ActiveX control disappears when the mouse hovers over the control if the titlebar is not visible.

Workaround: If the control has a windowless mode, use the windowless mode.

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
349832

Return
The mouse wheel scrolls the wrong control while ring control menu is displayed.
This behavior occurs if the focus is still on a different control when the ring drop-down menu is opened.

Workaround: N/A

Reported Version: 8.1    Resolved Version: N/A    Added: 07/22/2012
350412

Return
In some cases, the EVENT_LOST_FOCUS and EVENT_COMMIT events are not displayed in Operate mode when changing focus away from controls.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
350752

Return
A tree item tooltip continues to display when the cursor is over a tree item and another active window is in front of part of the tree item.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
350944

Return
The numeric control cannot have a transparent background.

Workaround: N/A

Reported Version: 6.0    Resolved Version: N/A    Added: 07/22/2012
351155

Return
LoadExternalModule does not guarantee that the module loaded is 16-byte aligned.
This behavior may cause errors when using third-party compilers.

Workaround: N/A

Reported Version: 2010    Resolved Version: N/A    Added: 07/22/2012
352408

Return
Pressing F1 on a function in the ActiveX Library or most of the Tools Libraries does not open the LabWindows/CVI Help to the topic for the specified function.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 07/22/2012
354450

Return
Using a very long string when setting the value of a variable in the Variables window may crash the LabWindows/CVI environment.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
354451

Return
A very long string value in the Add/Edit Tools Menu Item dialog box may crash LabWindows/CVI.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
354452

Return
A very long string value in the Project folder or File Folder option of the New Project from Template or New File from Template dialog boxes may crash LabWindows/CVI.

Workaround: N/A

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
354481

Return
User specified icons are not displayed in Windows Explorer for larger sizes in Windows Vista/7.
In certain situations, the icon displayed may be a cached icon rather than the icon you have specified.

Workaround: Follow the instructions in KnowledgeBase 5A6C270U: Cannot Update Custom Icon of an Executable in Windows 7 or Vista to remove the cached icon.

Reported Version: 8.5    Resolved Version: N/A    Added: 07/22/2012
355331

Return
Editing the RGB values of an RGB color in the Watch window doesn't also update the overall value of the variable in the parent node.
The value is updated, but the displayed value of the parent node is not updated.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
356421

Return
Entries in the Watch window may be dimmed incorrectly if multiple entries have the same symbol name.
Multiple entries with the same symbol name may exist because they have different scope.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
356470

Return
Building the sdk\stdio\demo.prj example project in a 64-bit configuration against the clang compiler causes an unrecoverable internal error.
Building the project located at C:\Users\Public\Documents\National Instruments\CVI2012\samples\sdk\stdio\demo.prj causes the unrecoverable error.

Workaround: N/A

Reported Version: 2012    Resolved Version: N/A    Added: 07/22/2012
356708

Return
The Source window cursor can persist after selecting text and editing a variable tooltip.
This behavior can cause two cursors to exist at the same time.

Workaround: Scroll the Source Editor window up/down to make the old cursor go away.N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
357245

Return
Local array in a thread that has exited may appear as still active in the Watch window.
This behavior can occur if the thread exited using the CmtExitThreadPoolThread function instead of return.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
358560

Return
Function name is not reported in Break On Library Errors message.

Workaround: N/A

Reported Version: 7.1    Resolved Version: N/A    Added: 07/22/2012
359304

Return
The modulo operation with 64-bit integers in a 32-bit configuration may produce incorrect results.
The result will likely be incorrect if the second operand is negative.

Workaround: N/A

Reported Version: 7.0    Resolved Version: N/A    Added: 07/22/2012
360314

Return
The LabWindows/CVI environment crashes when showing a time_t variable in the Watch or Variables window while debugging a 64-bit application with extended debugging enabled.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/22/2012
335983

Return
Tooltip for symbol values during debugging may appear on top of the editor's scrollbar.

Workaround: N/A

Reported Version: 8.0    Resolved Version: N/A    Added: 07/24/2012
337770

Return
Setting LabWindows/CVI to "Run as administrator" will open a new instance of LabWindows/CVI each time you open a file associated with LabWindows/CVI.

Workaround: If you want to use LabWindows/CVI as administrator you can check the "Run as administrator" option from the Advanced button of the Shortcut tab instead of the Compatibility tab. You can access these options by right-clicking the LabWindows/CVI icon on your desktop and selecting Properties.

Reported Version: 8.5    Resolved Version: N/A    Added: 07/24/2012
333302

Return
Auto Backup will provide an error if the file is marked as read-only.
This behavior is common if the file is stored in source control. Auto Backup may also take effect even if the file was not modified.

Workaround: Disable Auto Backup in Environment Options.

Reported Version: 8.0    Resolved Version: N/A    Added: 07/25/2012
335488

Return
Excluded import libraries that represent both 32-bit and 64-bit .lib files are no longer dimmed after switching configurations.
The .lib file is excluded but is not dimmed.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/25/2012
339287

Return
The Default index for combo box cell types in the Edit Table dialog box expands too far down if the value has multiple lines.

Workaround: N/A

Reported Version: 2009    Resolved Version: N/A    Added: 07/25/2012
364220

Return
Welcome Page PDF links do not work unless you are using Adobe Acrobat.
Most of the links in the What's New in LabWindows/CVI section of the Welcome Page do not work as expected. The link to See All Feature Descriptions works correctly.

Workaround: Set your default PDF reader to be Adobe Acrobat.

Reported Version: 2012    Resolved Version: N/A    Added: 07/25/2012
309845

Return
Tree control tooltip does not use the character set of the tree.
Hovering over an item with the mouse shows a tooltip with the item label if the label is longer than the visible area of tree control. That tooltip uses the native character set instead of the character set specified for the tree control.

Workaround: N/A

Reported Version: 9.0    Resolved Version: N/A    Added: 07/26/2012
362404

Return
The LabWindows/CVI Run-Time Engine displays incorrectly in LabVIEW Application Builder and TestStand Deployment Utility.
The Run-Time Engine will appear as "NI LabWindows/CVI Run-Time Engine @package.release.year@" instead of "NI LabWindows/CVI Run-Time Engine 2012". The incorrect text will appear in the LabVIEW Application Builder and TestStand Deployment Utility, but will appear correctly in the LabWindows/CVI Edit Installer dialog box.

Workaround: Refer to KB 5ZPDLIQW: Why does the LabWindows™/CVI Run-Time Engine Display Incorrectly in LabVIEW Application Builder and TestStand Deployment Utility? for more information.

Reported Version: 2012    Resolved Version: N/A    Added: 07/26/2012

Document last updated on 8/1/2012

0 Ratings | 0.00 out of 5
 Print |  PDF

Reader Comments | Submit a comment »

 

Legal
This tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial may be made available by National Instruments, the content in this tutorial may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision of related products and drivers. THIS TUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).