CalibrationCalibration Executive Updates for Version 2.0The following links provide update information for various Calibration Executive 2.0 calibration procedures. E Series Calibration Procedure ver 1.0
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\E Series\Limits directory that is found in the Calibration Executive directory.
Also, download the PXI-6070E update from the 'E Series Calibration Procedure ver 2.0' section below.
E Series Calibration Procedure ver 2.0
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\E Series\Limits directory that is found in the Calibration Executive directory.
NI5911 Calibration Procedure
To install this update, download the compressed file and extract its contents
into the Calibration Executive\Procedures\NI5911\ directory that is found in
the Calibration Executive directory.
NI 4060 Calibration Procedure
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\NI4060\ directory that is found in the Calibration Executive directory.
NI 4350/4351 Calibration Procedure
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\NI4350 NI4351\ directory that is found in the Calibration Executive directory.
In addition, there is a utility that will restore the EEPROM of the 4350/4351 to a correct working state if you already adjusted the 4350/4351 with the original procedure. Only use this utility if you have already adjusted the 4350/4351 with version 1.0 of the NI4350 NI4351 Procedure.
To use this utility, download the compressed file and extract its contents into the Calibration Executive\Procedures\NI4350 NI4351\ directory. Ensure that your 435x device is configued to Device #1 in Measurement and Automation Explorer, then run Fix435xEEPROM.exe that you extracted. This utility only works on Device #1.
SCXI-1100 Calibration Procedure
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\SCXI1100\ directory that is found in the Calibration Executive directory.
SCXI-1120D Calibration Procedure
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\SCXI1120\ directory that is found in the Calibration Executive directory.
4451/4452/4551/4552 (DSA) Calibration Procedure
To install this update, download the compressed file and extract its contents into the Calibration Executive\Procedures\DSA\ directory that is found in the Calibration Executive directory.
Download the Agilent 3325B IVI Instrument Driver Fluke 5500A/5520A Instrument Driver
To install this driver, download the compressed file and extract its contents into a temporary directory. Run Setup.exe or Setup95-NT40.exe (they are the same installer). If you need to transfer these files to another computer via floppy disk, copy Setup.exe because it can easily fit on a floppy disk.
If Setup.exe fails to install, run Setup95-NT40.exe instead.
TestStand 1.0.3 Engine for Windows 2000/ME
To install this driver, download the compressed file and extract its contents into a temporary directory. Run SetupTSEngine.exe. You will need to overwrite the TestStand installation in your Calibration Executive\TestStand directory. After installing, reboot your computer for the changes to take effect.
If you have any questions or comments please e-mail us at calibration@ni.com. |