Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Automatic Calibration Software

Calibration Executive 3.3.2
Calibration Executive relies on external calibration standards to verify and adjust the performance of data acquisition products. The resulting calibration constants are then stored in a protected portion of the device's memory. In addition, Calibration Executive provides reporting capabilities for documenting the calibration results.

Relying on an intuitive user interface, Calibration Executive guides you through the configuration and calibration procedure. If you are using the supported GPIB equipment, the entire calibration procedure is automated. If you do not have one of the supported instruments, Calibration Executive will step you through the calibration process. The links shown below provide images of the operator interface.

Main operator interface
Setup wizard - customer information
Setup wizard - standards information
Setup wizard - device information
Example calibration report
Example calibration data

A summary of supported products and system requirements is listed below:

C Series Devices
Verification & AdjustmentVerification Only
NI 9205NI 9201
NI 9206NI 9203
 NI 9211
 NI 9215
 NI 9217
 NI 9221
 NI 9225
 NI 9229
 NI 9237
 NI 9239
 NI 9263
 NI 9264
 NI 9265
Counter/Timer Devices
Verification & AdjustmentVerification Only
NI 6608NI 6601
 NI 6602
Data Acquisition (DAQ) Devices
Analog Output
Verification & AdjustmentVerification Only
NI 6703/6704
NI 6711/6713/6715 
NI 6722/6723 
NI 6731/6733 
B Series
Verification & AdjustmentVerification Only
NI 6010
NI 6013 
NI 6014 
DSA
Verification & AdjustmentVerification Only
NI 4451/4452/4551/4552
NI 4461/4462 
NI 4472/4474/4472B 
NI 4495/4496/4498 
E Series
Verification & AdjustmentVerification Only
NI AT-AI-16XE-10
NI AT-MIO-16DE-10 
NI AT-MIO-16E-1 
NI AT-MIO-16E-10 
NI AT-MIO-16E-2 
NI AT-MIO-16XE-10 
NI AT-MIO-16XE-50 
NI AT-MIO-64E-3 
NI DAQCard-6024E 
NI DAQCard-6036E 
NI DAQCard-6062E 
NI DAQCard-AI-16E-4 
NI DAQPad-6015 
NI DAQPad-6016 
NI DAQCard-AI-16XE-50 
NI DAQPad-6020E 
NI DAQPad-6052E 
NI DAQPad-6070E 
NI 6011E 
NI 6023E/6024E/6025E 
"NI 6030E/6031E/6032E/6033E/6034E/6035E/6036E" 
NI 6040E 
NI 6052E 
NI 6070E/6071E 
NI PCI-AI-16XE-10 
NI PCI-AI-64XE-10 
NI PCI-MIO-16E-1 
NI PCI-MIO-16E-4 
NI PCI-MIO-16XE-10 
NI PCI-MIO-16XE-50 
NI PCI-MIO-64E-1 
NI PCI-MIO-64XE-10 
Data Loggers
Verification & AdjustmentVerification Only
NI 4350/4351
M Series
Verification & AdjustmentVerification Only
"NI USB-6210/6211/6212/6215/6216/6218"
"NI 6220/6221/6224/6225/6229" 
"NI 6230/6232/6233/6236/6238/6239" 
"NI 6250/6251/6254/6255/6259" 
NI 6280/6281/6284/6289 
R Series
Verification & AdjustmentVerification Only
NI 7830R
NI 7831R 
NI 7833R 
NI 7841R 
NI 7842R 
NI 7851R 
NI 7852R 
S Series Devices
Verification & AdjustmentVerification Only
NI 6110/6111/6115 
NI 6120/6122/6123 
NI 6124 
NI 6132/6133 
NI 6143 
NI 6154 
SC Series
Verification & AdjustmentVerification Only
NI 4220
FieldPoint Modules
Verification & AdjustmentVerification Only
FP-AI-100/102/110/111/112
FP-AO-200/210 
FP-AIO-600/610 
FP-RTD-122/124 
FP-TC-120 
"cFP-AI-100/102/110/111/112" 
cFP-AO-200/210 
cFP-AIO-600/610 
cFP-RTD-122/124 
cFP-TC-120 
Modular Instruments
DMM
Verification & AdjustmentVerification Only
NI 4050
NI 4060 
NI 4065 
NI 4070 
NI 4071 
NI 4072 
Digitizers
Verification & AdjustmentVerification Only
NI 5102NI 5112
NI 5105 
NI 5114 
NI 5122 
NI 5124 
NI 5132 
NI 5133 
NI 5142 
NI 5152 
NI 5153 
NI 5154 
NI 5900 
NI 5911 
NI 5922 
High-Speed Digital I/O
Verification & AdjustmentVerification Only
NI 6551
NI 6552 
Power Supplies & SMUs
Verification & AdjustmentVerification Only
NI 4110
NI 4130 
RF
Verification & AdjustmentVerification Only
NI 5600NI 565x
NI 5610NI 5663
NI 5620NI 5673
Signal Generators
Verification & AdjustmentVerification Only
NI 5402
NI 5406 
NI 5412 
NI 5421 
NI 5422 
NI 5441 
NI 5442
PXI Timing and Synchronization
Verification & AdjustmentVerification Only
NI 6652/6653/6672—
SCXI-Modules
Verification & AdjustmentVerification Only
SCXI-1102/B/CSCXI-1100
SCXI-1104/C 
SCXI-1120/D 
SCXI-1121 
SCXI-1124 
SCXI-1125 
SCXI-1520 
SCXI-1600 

System Requirements

  • Windows 2000/XP
  • Pentium 600 MHz processor or better
  • 256 MBytes of RAM
  • 1 GB hard drive space
  • VGA monitor capable of 800x600 resolution, 256 colors

Note: Windows Vista is not yet supported. Windows 2000 requires service pack 4.

Required Calibration Equipment

Calibration Executive Updates
As new products are released, we try to add support for them in Calibration Executive. If your current version of Calibration Executive does not support some of our new data acquisition products, you may want to check the Calibration Executive Updates page.