Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Which DAQ System Is Right for You?

NI has developed a number of signal conditioning options to fit your particular DAQ system, featuring flexible signal connectivity, modularity, and software configurability. These options range from compact signal conditioning systems for portable applications (SCC) to rugged, multi-channel, USB-based systems for large applications requiring superior performance (SCXI).

1 - Select the right platform for your DAQ system application from the selection guide below.

2 - Customize the DAQ system for your sensor and signal measurements. Click on the links to learn more about SCXI, SCC, or other signal conditioning platforms.

1 - Select your platform 2 - Select your DAQ System  
  SCXI SCC SC Series Compact
Fieldpoint
5B
Sensors Plug&Play Support SCXI-1314T & BNC-2096 SC-2350 - - -
Millivolts/Volts SCXI-1102 SCC-AI Series PXI-4204 cFP-AI-110 5B30/31/40/41
Medium Voltage (60V) SCXI-1104/C SCC-AI Series PXI-4204 cFP-AI-102 -
High Voltage (300-1000V) SCXI-1125 - - - -
Isolated Analog Inputs SCXI-1125 SCC-AI Series & SCC-CI20 - cFP-AI-1xx Series 5B30/1 & 5B40/1
Current (0-20mA) SCXI-1102B/C SCC-CI20 - cFP-AI-110 5B32/42
Frequency Input SCXI-1126 SCC-FV01 PXI-4472 cFP-CTR-500 5B45/46
Thermocouples SCXI-1112 SCC-TC Series PXI-4351 cFP-TC-120 5B37/47
RTDs/Thermistors SCXI-1581 & SCXI 1102 SCC-RTD01 PXI-4351 cFP-RTD-122 5B34/35
Strain Gauges SCXI-1520 SCC-SG Series PXI-4220 cFP-SG-140 5B38
Force/Load/Torque SCXI-1520 SCC-SG24 PXI-4220 cFP-SG-140 -
Pressure/Flow SCXI-1520 SCC-SG24 PXI-4220 cFP-SG-140 -
LVDTs/RVDTs/Resolvers SCXI-1540 - - - -
Accelerometers SCXI-1530/1 SCC-ACC01 PXI-4472 - -
Analog Output SCXI-1124 SCC-CO20 & SCC-AO10 PXI-67xx cFP-AO-2xx Series 5B39/49
TTL/CMOS SCXI-116x SCC-DI01 PXI-65xx cFP-DI-3xx Series -
Switching SCXI-112x & SCXI-119x SCC-RLY01 PXI-25xx - -