1. Using this Switches Replacement Relay Guide
This guide is intended to cover replacement relays designed for use with NI Switches. It does not explicitly cover replacement parts for other NI product families such as DAQ. HSDIO, C Series, or reconfigurable I/O (formerly R Series). It also does not cover legacy or End of Life (EOL) parts or products.
- To determine the compatibility of your terminal or connector block accessory or your NI Switches cable with an NI Switch module or device, visit the NI Switch Cable and Accessory Compatibility Guide.
- To create your own cable or test fixture, or to repair an existing NI Switch cable or accessory, visit NI Switch Mating Connectors for Custom Solutions or Cables Guide.
- For assistance getting started connecting signals to your NI Switch see How to Connect Signals to an NI Switch.
2. How to Replace a Relay on Your Switch
If a relay on your NI Switch is broken or has failed you will need to perform the following tasks to replace it.
- Identify the correct replacement relay for your module or device. See the NI Replacement Relays and Manufacturer Part Numbers for relay orderable part numbers.
- Once you have the correct replacement relay, navigate to the NI-Switch Help. If you have installed NI-Switch on your system, the NI-Switch Help can be found in the <National Instruments>\NI-SWITCH\NI-SWITCH Documentation folder, or the NI-Switch Help can be found online.
- In the NI-Switch Help you will find guidance on replacing your relay by navigating to NI Switches Help>>Devices>><Model Number>>>Relay Replacement. Here you will find a step-by-step guide on how to replace relays on your switch module.
For example, a step-by-step guide on how to replace a relay in the NI PXIe-2526 can be found by navigating to NI Switches Help>>Devices>>NI PXIe-2526>>Relay Replacement.
3. NI Replacement Relays and Manufacturer Part Numbers
Switch Model | Relay Type | NI Orderable Part Number |
Manufacturer Part Number |
|||
---|---|---|---|---|---|---|
2510, 2522, 2523, 2737, 2738, 2739 | Electromechanical | 781089-10 | Tyco Electronics 5-1462039-8 | |||
2520 | Electromechanical | 782460-10 | Tyco Electronics IMB02CTS (1462041-5) | |||
2521, 2524, 2525, 2526 | Electromechanical | 782461-10 | Tyco Electronics 1462043-6 | |||
25271, 25681, 25691 | Electromechanical | 779356-01 | AXICOM (Tyco Electronics) IM42GR (3-1462037-1) | |||
Electromechanical | 782051-01 | AXICOM (Tyco Electronics) IM42PGR (5-1462039-7) | ||||
2564 | Electromechanical | 780262-01 | Fujitsu JY-5H-K | |||
2529 | Electromechanical | N/A | Aromat (NAiS) AGQ210A4H | |||
2565 | Electromechanical | 777880-01 | Aromat (NAiS) DSP1a-DC5V | |||
2530B | Reed | N/A | Coto 9012-05-11 | |||
2531, 2532, 2532B | Reed | N/A | Meder CRR05-1A | |||
2566 | Electromechanical | N/A | Aromat (NAiS) TQ2SA-5V | |||
25701 | Electromechanical - Through-Hole Mount | 781678-01 | AXICOM (Tyco Electronics) IM42PNS (7-1462039-8) | |||
Electromechanical - Surface Mount | 779356-01 | AXICOM (Tyco Electronics) IM42GR (3-1462037-1) | ||||
2571 | Electromechanical | 781678-01 | AXICOM (Tyco Electronics) IM42PNS (7-1462039-8) | |||
25751,2 | Electromechanical | 780386-01 | OMRON G6KU_2F-Y | |||
Electromechanical | 779356-01 | AXICOM (Tyco Electronics) IM42GR (3-1462037-1) | ||||
Electromechanical | 782051-01 | AXICOM (Tyco Electronics) IM42PGR (5-1462039-7) | ||||
2576 | Electromechanical | 780383-01 | OMRON G6JU-2P-Y DC4.5 | |||
2584 | Reed | N/A | Coto Technology 9104-05-11 | |||
2585. 2586 | Electromechanical | N/A | Potter & Brumfield (Tyco Electronics) RTB14005F (2-1419108-4) | |||
27203, 27223, 27253, 27273 | Reed | 781451-10 | Coto 9117-0001 | |||
Reed | 786914-01 | Standex-Meder UMS05-BV51101 | ||||
2810, 2811, 2812, 2813, 2814 | Electromechanical - Safety | 781089-10 | Tyco Electronics 5-1462039-8 | |||
Reed | 781450-10 | Meder MS05-BV50980 | ||||
28153, 28163, 28173 | Electromechanical - Safety | 781089-10 | Tyco Electronics 5-1462039-8 | |||
Reed | 781451-10 | Coto 9117-0001 | ||||
Reed | 786915-01 | Standex-Meder UMS05-BV51338 | ||||
2833, 2834 | Electromechanical - Safety | 781089-10 | Tyco Electronics 5-1462039-8 | |||
Electromechanical | 781678-01 | AXICOM (Tyco Electronics) IM42PNS (7-1462039-8) | ||||
1 The IM42GR and IM42PGR relays are drop in replacements. Some switch model revisions were built using different relays. Contact National Instruments to find out which relay was used on a specific device. 3 Some switch model revisions were built using different relays. Contact National Instruments to find out which relay was used on a specific device. |
||||||
4. Ordering Information
For more information on any of the listed NI orderable parts, please visit http://www.ni.com/contact-us/ to contact an NI representative. NI orderable parts listed in this guide without a product page can still be purchased by contacting NI.
For parts with a manufacturer part number, please contact the manufacturer or their vendors for further information about the product and purchasing. Manufacturer part numbers represent functionally equivalent replacements that are currently available from the specified manufacturer. This may differ from the part found on your device, module, cable or accessory as NI continuously revises and improves their products.
Some parts are custom made for NI or are common parts in industry, and do not have orderable part numbers. Please use the specifications provided to find an appropriate part.
5. Related Resources
- Find the parts need to make a custom cable, breakout fixture, replace connectors on NI Switch hardware
- Learn about the compatibility of NI Switch devices and modules with NI Switch cables and accessories.
- How Do I Track Relay Usage on NI Switch Products?
- Browse dimensional drawings for NI cables and accessories
- NI Product Manuals, Product Specifications, Installation Guides and more
- Products and Services: NI Switches
- Products and Services: PXI Switches Connectivity Accessories