This patch fixes the issues listed in the table below. National Instruments strongly recommends this patch for all LabVIEW 2013 SP1 installations. 

Issues Fixed in LabVIEW 2013 SP1 f6

ID Description
500664 Under certain conditions, the LabVIEW Digital Waveform Graph appears blank even with valid data present.
488388 The SMTP client could potentially not send an email or return errors when using cURL 7.34.0 or higher.
505820 LabVIEW-built applications with a large number of UI elements may encounter a DAbort condition referencing eventq.cpp



Issues Fixed in LabVIEW 2013 SP1 f5

ID Description
478801 LabVIEW is unable to return to the calling VI when debugging a reentrant VI with the "Suspend when called" execution setting enabled.
452438 Reentrant VIs set to "Suspend when called" do not execute when using "Step Into" button while debugging.
246317 The method App.Get VI.Qualified Name does not return the correct qualified name for VIs in a LabVIEW source distribution when the source distribution is in a LabVIEW library.
488436 The 64-bit TestStand Deployment Utility may fail to start or immediately crash when used with LabVIEW.
478458 In certain cases, the Start Asynchronous Call VI paired with an Open VI Reference VI set to "Enable simultaneous calls on reentrant VIs" (0x40) and "Prepare to call and forget" (0x80) can result in a memory leak.



Issues Fixed in LabVIEW 2013 SP1 f4

ID Description
473817 Launching an executable that calls a control in a packed project library can result in an error dialog "The VI is not executable. The full development version of LabVIEW is required to fix the errors. VI has an error of type 302208."
473514 TestStand ActiveX invoke nodes may not return the expected error 97 ("LabVIEW: A null or previously deleted refnum was passed in as an input.") when a null reference is used.
472865 Reordering diagram objects from front/back and then creating a subVI that includes selected controls may cause LabVIEW to crash. This is due to the VI becoming corrupt from front/back reordering of diagram objects.
435492 Calling a child class VI through Dynamic Dispatch from TestStand can initialize the child incorrectly and cause incorrect data to be passed.
445027 Calling multiple LabVIEW built .NET assemblies from a .NET language will cause the second assembly to fail with Error 1.


Note: In order to apply the change for CAR 473514 you need to recompile affected code. 
This can be accomplished by force recompiling the affected VI hierarchy: <Ctrl+Shift> + Run Button or by mass compiling.

Issues Fixed in LabVIEW 2013 SP1 f3

ID Description
445639 LabVIEW Packed Project Libraries loaded from outside a LabVIEW project can sometimes load broken.
448199 Wiring a cluster into a Bundle node inside an In Place Element Structure sometimes causes an extra memory allocation.
467722 Replacing controls can cause a crash if Property Nodes are not updated to accept the correct data type.


Note: The LabVIEW 2013 SP1 f3 Patch may cause an error when running certain executables built with TestStand. If you see the following error message when running your EXE, you may need to uninstall the LabVIEW 2013 SP1 Runtime Engine and then reinstall the Runtime Engine along with any dependencies:
The VI is not executable. The full development version of LabVIEW is Required to fix the errors. Vi has and error of type 302208.


Issues Fixed in LabVIEW 2013 SP1 f2

ID Description
440114 Executing a TestStand sequence with LabVIEW VIs in a user interface running in LabVIEW 2013 causes delays at the beginning of execution.
441783 LabVIEW Class VIs loaded from an unexpected path can sometimes load broken.
431956 Calling a LabVIEW Web Service repeatedly causes a memory leak.
457434 In LabVIEW 2013 SP1, removing a file from a class and then adding that file back to the same class can crash LabVIEW.
453896 Error message encountered during TestStand Deployment Utility build process may show incorrect list of VIs.



Issues Fixed in LabVIEW 2013 SP1 f1

ID Description
447058 Under certain conditions, LabVIEW cannot create a functional .NET interop assembly if the assembly contains LabVIEW Class.
442743 Cutting text from a Free Label with the Auto Tool disabled can crash LabVIEW.
445981 Custom ActiveX Control, which returns uInt64 data in LabVIEW, results in a memory leak.
445636 PostScript printing of graphical elements in LabVIEW does not work correctly.



Related Links: 
Drivers and Updates: LabVIEW 2013 SP1 (32-bit) f6 Patch 
Drivers and Updates: LabVIEW 2013 SP1 (64-bit) f6 Patch 
Drivers and Updates: LabVIEW Run-Time Engine 2013 SP1 (32-bit)
Drivers and Updates: LabVIEW Run-Time Engine 2013 SP1 (64-bit)

Back to Top

Bookmark & Share


Ratings

Rate this document

Answered Your Question?
Yes No

Submit